NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 27, 2024.

Search: Author = N.Zhou

Found 3 matches.

Back to query form



2024YA08      Phys.Rev.Lett. 132, 152502 (2024)

X.Yan, Zh.Cheng, A.Abdukerim, Z.Bo, W.Chen, X.Chen, Ch.Cheng, X.Cui, Y.Fan, D.Fang, Ch.Fu, M.Fu, L.Geng, K.Giboni, L.Gu, X.Guo, Ch.Han, K.Han, Ch.He, J.He, D.Huang, Y.Huang, J.Huang, Zh.Huang, R.Hou, Y.Hou, X.Ji, Y.Ju, Ch.Li, J.Li, M.Li, Sh.Li, T.Li, Q.Lin, J.Liu, X.Lu, C.Lu, L.Luo, Y.Luo, W.Ma, Y.Ma, Y.Mao, Y.Meng, X.Ning, B.Pang, N.Qi, Zh.Qian, X.Ren, N.Shaheed, X.Shang, X.Shao, G.Shen, L.Si, W.Sun, A.Tan, Y.Tao, A.Wang, M.Wang, Q.Wang, Sh.Wang, S.Wang, W.Wang, X.Wang, Zh.Wang, Y.Wei, M.Wu, W.Wu, J.Xia, M.Xiao, X.Xiao, P.Xie, B.Yan, J.Yang, Y.Yang, Y.Yao, Ch.Yu, Y.Yuan, Zh.Yuan, X.Zeng, D.Zhang, M.Zhang, P.Zhang, Sh.Zhang, Sh.Zhang, T.Zhang, W.Zhang, Y.Zhang, Y.Zhang, Y.Zhang, L.Zhao, Q.Zheng, J.Zhou, N.Zhou, X.Zhou, Y.Zhou, Y.Zhou, for the PandaX Collaboration

Searching for Two-Neutrino and Neutrinoless Double Beta Decay of 134Xe with the PandaX-4T Experiment

RADIOACTIVITY 134Xe(2β-); measured decay products, Eβ, Iβ; deduced two-neutrino and neutrinoless T1/2 limits. Comparison with available data. The cylindrical active volume PandaX-4T dual-phase TPC.

doi: 10.1103/PhysRevLett.132.152502
Citations: PlumX Metrics


2022ZH04      Phys.Rev. C 105, 014604 (2022)

D.Zhang, Y.Li, J.Bao, C.Fu, M.Guan, Y.He, X.Ji, H.Jia, Y.Li, J.Liu, J.Xia, W.Xiong, J.You, C.Yuan, N.Zhou

83Rb/83mKr production and cross-section measurement with 3.4 MeV and 20 MeV proton beams

NUCLEAR REACTIONS Kr(p, n)83Rb/84Rb/86Rb, E=3.4 MeV beam from China Institute of Atomic Energy; Kr(p, n), E=20 MeV beam from Institute of Modern Physics; measured Eγ, Iγ, total generated radioactivities and thick-target yields for rubidium isotope. 83mKr/83Rb; measured production rate of 83mKr from 83Rb decay; produced 83mKr yielded enough statistics for detector calibration injected into the PandaX-II liquid xenon detector for dark matter studies. Relevance to calibration source such as short half-life 83mKr for liquid xenon or liquid argon detectors in experiments dealing with search for dark matter.

doi: 10.1103/PhysRevC.105.014604
Citations: PlumX Metrics


2019NI10      Chin.Phys.C 43, 113001 (2019)

K.Ni, Y.Lai, A.Abdukerim, W.Chen, X.Chen, Y.Chen, X.Cui, Y.Fan, D.Fang, C.Fu, L.Geng, K.Giboni, F.Giuliani, L.Gu, X.Guo, K.Han, C.He, D.Huang, Y.Huang, Y.Huang, Z.Huang, P.Ji, X.Ji, Y.Ju, K.Liang, H.Liu, J.Liu, W.Ma, Y.Ma, Y.Mao, Y.Meng, P.Namwongsa, J.Ning, X.Ning, X.Ren, C.Shang, L.Si, A.Tan, A.Wang, H.Wang, M.Wang, Q.Wang, S.Wang, X.Wang, Z.Wang, M.Wu, S.Wu, J.Xia, M.Xiao, P.Xie, B.Yan, J.Yang, Y.Yang, C.Yu, J.Yuan, D.Zhang, H.Zhang, T.Zhang, L.Zhao, Q.Zheng, J.Zhou, N.Zhou, X.Zhou

Searching for neutrino-less double beta decay of 136Xe with PandaX-II liquid xenon detector

RADIOACTIVITY 136Xe(2β-); measured decay products, Eβ, Iβ; deduced T1/2 and Majorana neutrino mass limits. Comparison with available data.

doi: 10.1088/1674-1137/43/11/113001
Citations: PlumX Metrics

Data from this article have been entered in the XUNDL database. For more information, click here.


Back to query form