2023KE09      Phys.Rev. C 108, 024603 (2023)

K.J.Kelly, M.Devlin, J.M.O'Donnell, D.Neudecker, A.E.Lovell, R.C.Haight, C.Y.Wu, R.Henderson, E.A.Bennett, T.Kawano, J.L.Ullmann, N.Fotiades, J.Henderson, S.M.Mosby, T.N.Taddeucci, P.Talou, M.C.White, J.A.Gomez, H.Y.Lee

Measurement of the 238U(n, f) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons with 1.5-20 MeV energy

NUCLEAR REACTIONS 238U(n, F), E=1.5-20 MeV; measured fission fragments, En, In, neutron time-of-flight, (fragment)n-coin; deduced prompt fission neutron spectrum (PFNS). Systematic trends in PFNS and PFNS ratios for 239Pu, 235U, and 238U obtained in series of Chi-Nu experiments. Comparison to other experimental results, CGMF calculations and data from JEFF-3.3, JENDL-5.0. ENDF/B-VIII libraries. Pulsed white neutron source at Weapons Neutron Research (WNR) facility of the Los Alamos Neutron Science Center (LANSCE). Li-glass array consisting of 22 detectors and liquid scintillator array consisting of 54 detector used for neutron detection, while PPAC used for detecting fission fragments in the frame of Chi-Nu experiment.

doi: 10.1103/PhysRevC.108.024603
Citations: PlumX Metrics


2022GA37      Nucl.Instrum.Methods Phys.Res. A1037, 166853 (2022)

P.Gastis, J.R.Winkelbauer, D.S.Connolly, S.A.Kuvin, S.M.Mosby, C.J.Prokop, I.Stetcu

Absolute mass calibration of fission product distributions measured with the E-υ method

RADIOACTIVITY 252Cf(SF); measured decay products, Eγ, Iγ. 92Rb; deduced fission product yields. The single-arm SPIDER spectrometer.

doi: 10.1016/j.nima.2022.166853
Citations: PlumX Metrics


2022KE01      Phys.Rev. C 105, 044615 (2022)

K.J.Kelly, J.A.Gomez, M.Devlin, J.M.O'Donnell, D.Neudecker, A.E.Lovell, R.C.Haight, C.Y.Wu, R.Henderson, T.Kawano, E.A.Bennett, S.M.Mosby, J.L.Ullmann, N.Fotiades, J.Henderson, T.N.Taddeucci, H.Y.Lee, P.Talou, M.C.White

Measurement of the 235U(n, f) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

NUCLEAR REACTIONS 235U(n, F), E=0.01-10 MeV; measured In, En, neutron time-of-flight, fission fragments, neutrons angular distributions, (fragment)n-coin; deduced prompt fission neutron spectrum (PFNS), components corresponding to first-, second-, and third-chance fission as well as pre-equilibrium neutron emission preceding fission, mean PFNS energy, ratio to PFNMS obtained in 239Pu(n, F) reaction. Experiment performed as a part of Chi-Nu project aimed to measure the PFNS of major actinides with the Weapons Neutron Research (WNR) facility at the Los Alamos Neutron Science Center (LANSCE). The results are compared with other experimental data, CGMF calculations and selected nuclear data evaluations - ENDF/B-VIII.0, JEFF-3.3, JENDL-5.0.

doi: 10.1103/PhysRevC.105.044615
Citations: PlumX Metrics


2022KO29      Eur.Phys.J. A 58, 195 (2022)

P.E.Koehler, J.L.Ullmann, A.J.Couture, S.M.Mosby

Constraining the nuclear spin distribution using improved 197Au neutron resonance parameters

NUCLEAR REACTIONS 197Au(n, X), E<3 keV; measured reaction products, En, In; deduced transmission, resonance parameters, distributions of total radiation widths for 197Au neutron resonances . R-matrix analysis. Comparison with available data, ENDF library. An early version of the Device for Indirect Capture Experiments on Radionuclides (DICER), which is under development at the Los Alamos Neutron Science Center (LANSCE).

doi: 10.1140/epja/s10050-022-00842-3
Citations: PlumX Metrics

Data from this article have been entered in the EXFOR database. For more information, access X4 dataset14796.


2020KE05      Phys.Rev. C 102, 034615 (2020)

K.J.Kelly, M.Devlin, J.M.O'Donnell, J.A.Gomez, D.Neudecker, R.C.Haight, T.N.Taddeucci, S.M.Mosby, H.Y.Lee, C.Y.Wu, R.Henderson, P.Talou, T.Kawano, A.E.Lovell, M.C.White, J.L.Ullmann, N.Fotiades, J.Henderson, M.Q.Buckner

Measurement of the 239Pu(n, f) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy 1-20 MeV

NUCLEAR REACTIONS 239Pu(n, F), E=1-20 MeV; measured outgoing prompt fission neutron spectrum (PFNS) in the range of E(n)=0.01-10 MeV, I(n) using Li-glass detector array and 54-detector EJ-309 liquid scintillator array in Chi-Nu experiment at the WNR-LANSCE-Los Alamos facility; deduced correlation matrix for PFNS from the Li-glass and the liquid scintillator. Comparison of present PFNS results with previous experimental results, and with evaluated data in ENDF/B-VIII.0 and JEFF-3.3 libraries.

doi: 10.1103/PhysRevC.102.034615
Citations: PlumX Metrics

Data from this article have been entered in the EXFOR database. For more information, access X4 dataset14682.


2019KE04      Phys.Rev.Lett. 122, 072503 (2019)

K.J.Kelly, T.Kawano, J.M.O'Donnell, J.A.Gomez, M.Devlin, D.Neudecker, P.Talou, A.E.Lovell, M.C.White, R.C.Haight, T.N.Taddeucci, S.M.Mosby, H.Y.Lee, C.Y.Wu, R.Henderson, J.Henderson, M.Q.Buckner

Preequilibrium Asymmetries in the 239Pu(n, f) Prompt Fission Neutron Spectrum

NUCLEAR REACTIONS 239Pu(n, F), E=15-17.5 MeV; measured reaction products, En, In; deduced neutron excess of the preequilibrium prefission distribution above the postfission neutron spectrum. Comparison with theoretical calculations.

doi: 10.1103/PhysRevLett.122.072503
Citations: PlumX Metrics


2019WI03      Phys.Rev. C 99, 024318 (2019)

J.R.Winkelbauer, S.M.Mosby, A.Couture, H.Y.Lee, J.L.Ullmann, T.Kawano, G.Rusev, M.Jandel, M.Krticka

Statistical neutron capture in the limit of low nuclear level density

NUCLEAR REACTIONS 96Zr, 208Pb(n, γ), E=thermal, 301, 3818, 4133, 5443, 5971, 9004, 17779 eV; measured Eγ, Iγ, γγ-coin, Spectra of γ-ray cascades using DANCE array at the LANSCE-LANL facility. 97Zr; deduced photon strength function (γPSF), multiplicity distributions for resonances. Comparison with simulated γ spectra from DICEBOX calculations for the cascades from the capture state and neutron resonances, and with ENSDF/B-VII.1 evaluation. Maxwellian averaged cross section (MACS).

doi: 10.1103/PhysRevC.99.024318
Citations: PlumX Metrics


2018DE08      Nucl.Data Sheets 148, 322 (2018)

M.Devlin, J.A.Gomez, K.J.Kelly, R.C.Haight, J.M.O'Donnell, T.N.Taddeucci, H.Y.Lee, S.M.Mosby, B.A.Perdue, N.Fotiades, J.L.Ullmann, C.Y.Wu, B.Bucher, M.Q.Buckner, R.A.Henderson, D.Neudecker, M.C.White, P.Talou, M.E.Rising, C.J.Solomon

The Prompt Fission Neutron Spectrum of 235U(n, f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

NUCLEAR REACTIONS 235U(n, F), E=0.7-20 MeV; measured reaction products, En, In, TOF; deduced prompt fission neutron spectrum, σ(E).

doi: 10.1016/j.nds.2018.02.008
Citations: PlumX Metrics


2017KI11      Nucl.Instrum.Methods Phys.Res. A874, 57 (2017)

L.E.Kirsch, M.Devlin, S.M.Mosby, J.A.Gomez

A new measurement of the 6Li(n, α)t cross section at MeV energies using a 252Cf fission chamber and 6Li scintillators

NUCLEAR REACTIONS 6Li(n, α), E<10 MeV; measured reaction products, Eα, Iα, En, In, TOF; deduced σ. Comparison with ENDF/B-VII.1 library, available data.

doi: 10.1016/j.nima.2017.08.046
Citations: PlumX Metrics

Data from this article have been entered in the EXFOR database. For more information, access X4 dataset14483.


2013RU14      Phys.Rev. C 88, 057602 (2013)

G.Rusev, M.Jandel, M.Krticka, C.W.Arnold, T.A.Bredeweg, A.Couture, W.A.Moody, S.M.Mosby, J.L.Ullmann

Cascade γ rays following capture of thermal neutrons on 113Cd

NUCLEAR REACTIONS 113Cd(n, γ), E=0.178 eV; measured Eγ, Iγ, γγ-coin using DANCE array of BaF2 detectors at LANSCE-LANL facility; deduced multiplicity of γ cascades. DICEBOX analysis. GEANT4 simulations. Comparison with ENDF-6 evaluation.

doi: 10.1103/PhysRevC.88.057602
Citations: PlumX Metrics


2008DE29      Phys.Rev. C 78, 044303 (2008)

D.H.Denby, P.A.DeYoung, T.Baumann, D.Bazin, E.Breitbach, J.Brown, N.Frank, A.Gade, C.C.Hall, J.Hinnefeld, C.R.Hoffman, R.Howes, R.A.Jenson, B.Luther, S.M.Mosby, C.W.Olson, W.A.Peters, A.Schiller, A.Spyrou, M.Thoennessen

Ground state energy and width of 7He from 8Li proton knockout

NUCLEAR REACTIONS Be(8Li, X), E=41 MeV/nucleon; measured particle spectra, angular distributions. Deduced energy of ground-state resonances. 7He; deduced ground-state energies and widths.

doi: 10.1103/PhysRevC.78.044303
Citations: PlumX Metrics

Data from this article have been entered in the XUNDL database. For more information, click here.