NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 25, 2024.

Search: Author = J.C.Bale

Found 7 matches.

Back to query form



2020LE06      J.Phys.(London) G47, 045113 (2020)

E.Leistenschneider, R.Klawitter, A.Lennarz, M.Alanssari, J.C.Bale, B.R.Barquest, U.Chowdhury, A.Finlay, A.T.Gallant, B.Kootte, D.Lascar, K.G.Leach, A.J.Mayer, D.Short, C.Andreoiu, G.Gwinner, M.E.Wieser, J.Dilling, A.A.Kwiatkowski

Diversifying beam species through decay and recapture ion trapping: a demonstrative experiment at TITAN-EBIT

RADIOACTIVITY 30Mg, 30Al(β-) [from U(p, X), E=480 MeV]; measured decay products, Eγ, Iγ; deduced γ-ray energies, population and charge-state evolutions and in-trap decay at TITAN-EBIT, identification of daughter species. TRIUMF's ISOL facility, the isotope separator and accelerator (ISAC).

ATOMIC MASSES 30Mg, 30Al; measured ToF-ICR resonance frequencies; deduced atomic mass excesses. Comparison with available data.

doi: 10.1088/1361-6471/ab6ee1
Citations: PlumX Metrics


2017GA20      Phys.Rev. C 96, 024325 (2017)

A.T.Gallant, M.Alanssari, J.C.Bale, C.Andreoiu, B.R.Barquest, U.Chowdhury, J.Even, A.Finlay, D.Frekers, G.Gwinner, R.Klawitter, B.Kootte, A.A.Kwiatkowski, D.Lascar, K.G.Leach, E.Leistenschneider, A.Lennarz, A.J.Mayer, D.Short, R.Thompson, M.Wieser, D.Lunney, J.Dilling

Mass determination near N=20 for Al and Na isotopes

ATOMIC MASSES 31,32Na, 29,34,35Al; measured cyclotron frequencies and mass excesses by time-of-flight ion-cyclotron-resonance (TOF-ICR) technique using the TITAN Penning trap mass spectrometer at ISAC-TRIUMF; deduced S(2n). Radioactive isotopes produced via the isotope separator on-line (ISOL) technique by a 480-MeV proton beam impinging on a UCx target, followed by the separation of sodium isotopes by surface ionization, and aluminum isotopes by the TRIUMF Resonant Ionization Laser Ion Source (TRILIS). Comparison with previous experimental values and mass evaluations. Systematics of S(2n) values for N=18-25 Na, Mg, and Al isotopic chains.

doi: 10.1103/PhysRevC.96.024325
Citations: PlumX Metrics


2015KW01      Phys.Rev. C 92, 061301 (2015)

A.A.Kwiatkowski, C.Andreoiu, J.C.Bale, A.Chaudhuri, U.Chowdhury, S.Malbrunot-Ettenauer, A.T.Gallant, A.Grossheim, G.Gwinner, A.Lennarz, T.D.Macdonald, T.J.M.Rauch, B.E.Schultz, S.Seeraji, M.C.Simon, V.V.Simon, D.Lunney, A.Poves, J.Dilling

Observation of a crossover of S2n in the island of inversion from precision mass spectrometry

ATOMIC MASSES 27,29,30,31,32,33,34Al; measured TOF-ICR resonance, mass excess using Ion Trap for Atomic and Nuclear science (TITAN) Penning-trap facility at TRIUMF. Comparison with AME-2012, and previous experimental values. Systematics of S(2n) values for 28,29,30,31,32,33,34,35,36,37Mg, 29,30,31,32,33,34,35,36,37,38Al, comparison of experimental and theoretical values; deduced crossover at N=21 in the island of inversion. Large-scale shell-model calculations.

doi: 10.1103/PhysRevC.92.061301
Citations: PlumX Metrics


2014KW01      Hyperfine Interactions 225, 143 (2014)

A.A.Kwiatkowski, C.Andreoiu, J.C.Bale, T.Brunner, A.Chaudhuri, U.Chowdhury, P.Delheij, S.Ettenauer, D.Frekers, A.T.Gallant, A.Grossheim, G.Gwinner, F.Jang, A.Lennarz, T.Ma, E.Mane, M.R.Pearson, B.E.Schultz, M.C.Simon, V.V.Simon, J.Dilling

TITAN: An ion trap facility for on-line mass measurement experiments

doi: 10.1007/s10751-013-0892-8
Citations: PlumX Metrics


2014MA21      Phys.Rev. C 89, 044318 (2014)

T.D.Macdonald, B.E.Schultz, J.C.Bale, A.Chaudhuri, U.Chowdhury, D.Frekers, A.T.Gallant, A.Grossheim, A.A.Kwiatkowski, A.Lennarz, M.C.Simon, V.V.Simon, J.Dilling

Precision Penning-trap measurement to investigate the role of the51Cr (e-, νe) 51V Q value in the gallium anomaly

ATOMIC MASSES 51Cr, 51V; measured cyclotron-frequencies, TOF-ICR resonances using TITAN system consisting of radio frequency quadrupole (RFQ) beam cooler and buncher, an electron beam ion trap (EBIT), and a Penning trap (MPET) at ISAC-TRIUMF facility; deduced Q value for EC decay of 51Cr. Comparison with AME-2012 evaluation. Relevance to solar neutrino experiments SAGE and GALLEX.

RADIOACTIVITY 51Cr(EC); measured precise Q(EC) value using TITAN system for precise mass measurements at ISAC-TRIUMF facility.

doi: 10.1103/PhysRevC.89.044318
Citations: PlumX Metrics


2013FR13      Phys.Lett. B 722, 233 (2013)

D.Frekers, M.C.Simon, C.Andreoiu, J.C.Bale, M.Brodeur, T.Brunner, A.Chaudhuri, U.Chowdhury, J.R.C.Lopez-Urrutia, P.Delheij, H.Ejiri, S.Ettenauer, A.T.Gallant, V.Gavrin, A.Grossheim, M.N.Harakeh, F.Jang, A.A.Kwiatkowski, J.Lassen, A.Lennarz, M.Luichtl, T.Ma, T.D.Macdonald, E.Mane, D.Robertson, B.E.Schultz, V.V.Simon, A.Teigelhofer, J.Dilling

Penning-trap Q-value determination of the 71Ga(ν, e-)71Ge reaction using threshold charge breeding of on-line produced isotopes

ATOMIC MASSES 71Ga, 71Ge; measured TOF, TOF-ICR, ion cyclotron resonance spectra; deduced Q-value and its uncertainty. TITAN Penning trap at ISAC/TRIUMF, comparison with AME data.

doi: 10.1016/j.physletb.2013.04.019
Citations: PlumX Metrics


2012GA29      Phys.Rev.Lett. 109, 032506 (2012)

A.T.Gallant, J.C.Bale, T.Brunner, U.Chowdhury, S.Ettenauer, A.Lennarz, D.Robertson, V.V.Simon, A.Chaudhuri, J.D.Holt, A.A.Kwiatkowski, E.Mane, J.Menendez, B.E.Schultz, M.C.Simon, C.Andreoiu, P.Delheij, M.R.Pearson, H.Savajols, A.Schwenk, J.Dilling

New Precision Mass Measurements of Neutron-Rich Calcium and Potassium Isotopes and Three-Nucleon Forces

ATOMIC MASSES 51,52Ca, 51K; measured TOF-ICR resonances, average frequency ratios; deduced masses. Comparison with available data. TRIUMF TITAN trap, comparison with available data, KB3G and GXPF1A effective interactions.

doi: 10.1103/PhysRevLett.109.032506
Citations: PlumX Metrics


Back to query form