NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 26, 2024.

Search: Author = S.Sturm

Found 10 matches.

Back to query form



2023HE18      Phys.Rev.Lett. 131, 253002 (2023)

F.Heisse, M.Door, T.Sailer, P.Filianin, J.Herkenhoff, C.M.Konig, K.Kromer, D.Lange, J.Morgner, A.Rischka, Ch.Schweiger, B.Tu, Y.N.Novikov, S.Eliseev, S.Sturm, K.Blaum

High-Precision Determination of g Factors and Masses of 20Ne9+ and 22Ne9+

ATOMIC MASSES 20,22Ne; measured the cyclotron-frequency ratio; deduced individual bound electron g factors, atomic masses. Comparison with available data. The PENTATRAP and A LPHATRAP experiments are both cryogenic Penning-trap setups located at the Max Planck Institute for Nuclear Physics in Heidelberg.

doi: 10.1103/PhysRevLett.131.253002
Citations: PlumX Metrics


2021FI03      Phys.Rev.Lett. 127, 072502 (2021)

P.Filianin, C.Lyu, M.Door, K.Blaum, W.J.Huang, M.Haverkort, P.Indelicato, C.H.Keitel, K.Kromer, D.Lange, Y.N.Novikov, A.Rischka, R.X.Schussler, Ch.Schweiger, S.Sturm, S.Ulmer, Z.Harman, S.Eliseev

Direct Q-Value Determination of the β- Decay of 187Re

ATOMIC MASSES 187Os, 187Re; measured cyclotron frequency ratio; deduced mass difference, β-decay Q-value. Comparison with AME-2016 evaluation.

doi: 10.1103/PhysRevLett.127.072502
Citations: PlumX Metrics


2019AR06      Phys.Rev.Lett. 122, 253001 (2019)

I.Arapoglou, A.Egl, M.Hocker, T.Sailer, B.Tu, A.Weigel, R.Wolf, H.Cakir, V.A.Yerokhin, N.S.Oreshkina, V.A.Agababaev, A.V.Volotka, D.V.Zinenko, D.A.Glazov, Z.Harman, C.H.Keitel, S.Sturm, K.Blaum

g Factor of Boronlike Argon 40Ar12+

ATOMIC PHYSICS 40Ar; measured frequencies; deduced resonances, the ground-state g factor of boronlike argon with uncertainties.

doi: 10.1103/PhysRevLett.122.253001
Citations: PlumX Metrics


2019HE19      Phys.Rev. A 100, 022518 (2019)

F.Heisse, S.Rau, F.Kohler-Langes, W.Quint, G.Werth, S.Sturm, K.Blaum

High-precision mass spectrometer for light ions

ATOMIC MASSES 1H, 16O; measured cyclotron frequencies; deduced masses. A cryogenic multi-Penning-trap setup, LIONTRAP (Light-Ion Trap).

doi: 10.1103/PhysRevA.100.022518
Citations: PlumX Metrics


2017HE14      Phys.Rev.Lett. 119, 033001 (2017)

F.Heisse, F.Kohler-Langes, S.Rau, J.Hou, S.Junck, A.Kracke, A.Mooser, W.Quint, S.Ulmer, G.Werth, K.Blaum, S.Sturm

High-Precision Measurement of the Proton's Atomic Mass

ATOMIC MASSES 1H; measured proton axial frequency; deduced precise mass value. Penning-trap system, comparison with CODATA value.

doi: 10.1103/PhysRevLett.119.033001
Citations: PlumX Metrics


2017ZA06      Phys.Rev. A 96, 012502 (2017)

J.Zatorski, B.Sikora, S.G.Karshenboim, S.Sturm, F.Kohler-Langes, K.Blaum, C.H.Keitel, Z.Harman

Extraction of the electron mass from g-factor measurements on light hydrogenlike ions

ATOMIC PHYSICS 4He, 12C, 28Si; analyzed available data on Penning-trap measurements of the Larmor and cyclotron frequency ratio; deduced electron mass using a hydrogenlike 12C and the corresponding theoretical value of the bound-electron g factor. Comparison with available data.

doi: 10.1103/PhysRevA.96.012502
Citations: PlumX Metrics


2016KO45      Nat. Commun. 7, 10246 (2016)

F.Kohler, K.Blaum, M.Block, S.Chenmarev, S.Eliseev, D.A.Glazov, M.Goncharov, J.Hou, A.Kracke, D.A.Nesterenko, Y.N.Novikov, W.Quint, E.Minaya Ramirez, V.M.Shabaev, S.Sturm, A.V.Volotka, G.Werth

Isotope dependence of the Zeeman effect in lithium-like calcium

ATOMIC MASSES 40,48Ca; measured cyclotron frequency ratio. 48Ca; deduced masses, g-factors. Comparison with theoretical calculations.

doi: 10.1038/ncomms10246
Citations: PlumX Metrics


2014ST05      Nature(London) 506, 467 (2014)

S.Sturm, K.Kohler, J.Zatorski, A.Wagner, Z.Harman, G.werth, W.Quint, C.H.Keitel, K.Blaum

High-precision measurement of the atomic mass of the electron

ATOMIC MASSES A=0; measured cyclotron frequency ratio of hydrogen-like 12C+5+; deduced electron mass. QED calculations, comparison with CODATA value.

doi: 10.1038/nature13026
Citations: PlumX Metrics


2010BL09      Eur.Phys.J. A 44, 363 (2010)

B.Blank, A.Bey, I.Matea, J.Souin, L.Audirac, M.J.G.Borge, G.Canchel, P.Delahaye, F.Delalee, C.-E.Demonchy, R.Dominguez-Reyes, L.M.Fraile, J.Giovinazzo, Tran Trong Hui, J.Huikari, D.Lunney, F.Munoz, J.-L.Pedroza, C.Plaisir, L.Serani, S.Sturm, O.Tengblad, F.Wenander

Precise half-life measurements for 38Ca and 39Ca

RADIOACTIVITY 38Ca(β+), 39Ca(β+)[from Ti(p, X), E=1.4 GeV]; measured CaF molecule ToF, Eβ, Iβ(t); deduced T1/2. Comparison with other results.

doi: 10.1140/epja/i2010-10958-2
Citations: PlumX Metrics

Data from this article have been entered in the XUNDL database. For more information, click here.


2009KE07      Eur.Phys.J. A 42, 311 (2009)

J.Ketelaer, K.Blaum, M.Block, K.Eberhardt, M.Eibach, R.Ferrer, S.George, F.Herfurth, J.Ketter, Sz.Nagy, J.Repp, L.Schweikhard, C.Smorra, S.Sturm, S.Ulmer

Recent developments in ion detection techniques for Penning trap mass spectrometry at TRIGA-TRAP

doi: 10.1140/epja/i2008-10711-6
Citations: PlumX Metrics


Back to query form