NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of May 8, 2024.

Search: Author = J.H.Chao

Found 6 matches.

Back to query form



2001CH94      Appl.Radiat.Isot. 55, 549 (2001)

J.-H.Chao, P.-C.Hsu, H.-M.Liu

Measurement of high dose rates by photon activation of indium foils

NUCLEAR REACTIONS 113,115In(γ, γ'), E=spectrum; measured isomer activation yields; deduced effective σ. Cobalt source, application to dose rate measurement discussed.

doi: 10.1016/S0969-8043(01)00076-8
Citations: PlumX Metrics


1997CH50      Nucl.Instrum.Methods Phys.Res. A385, 161 (1997)

J.-H.Chao, N.Huan

Measurement of Neutron Dose by a Moderating Germanium Detector

NUCLEAR REACTIONS Ge(n, γ), E=thermal; measured Eγ, Iγ; deduced detector neutron detection characteristics. Moderating neutron dosimeter.

doi: 10.1016/S0168-9002(96)00873-X
Citations: PlumX Metrics


1996CH50      Nucl.Instrum.Methods Phys.Res. A372, 275 (1996)

J.-H.Chao, C.-L.Tseng

Determination of 135Cs by Neutron Activation Analysis

RADIOACTIVITY 136Cs(β-) [from 135Cs(n, γ), E=thermal]; measured γ spectra; deduced 135Cs, 137Cs/135Cs ratio in radioactive, radwaste samples.

doi: 10.1016/0168-9002(95)01296-6
Citations: PlumX Metrics


1994CH57      Appl.Radiat.Isot. 45, 1189 (1994)

J.-H.Chao

252Cf as an Isotopic Neutron Source for Elemental Analysis by Neutron Inelastic Scattering: Comparison with 241Am-Be

NUCLEAR REACTIONS 23Na, 24Mg, 27Al, 28Si, 56Fe, 60Ni, 63,65Cu, 64,66,68Zn, 206,207,208Pb, 209Bi(n, n'γ), E=radioactive, fission sources; measured prompt γ spectra; deduced mineral elements relative detection sensitivities. Bulk sample analysis.

doi: 10.1016/0969-8043(94)90035-3
Citations: PlumX Metrics


1993CH19      Appl.Radiat.Isot. 44, 605 (1993)

J.-H.Chao

Neutron-Induced Gamma-Rays in Germanium Detectors

NUCLEAR REACTIONS Ge(n, γ), E=thermal; measured γ-spectra; deduced prompt, delayed γ-ray contributions to spectral background, remnant activities in detector. Hyperpure Ge detector target.

doi: 10.1016/0969-8043(93)90094-Q
Citations: PlumX Metrics


1991LE02      Appl.Radiat.Isot. 42, 547 (1991)

C.-J.Lee, J.-H.Chao, C.Chung

High-Energy Gamma Ray Spectrometer Using Bismuth Germanate Detector

RADIOACTIVITY 16N [from 16O(n, p), E=reactor]; measured Eγ, Iγ. High energy γ-spectrometer, bismuth germante detector.

doi: 10.1016/0883-2889(91)90160-3
Citations: PlumX Metrics


Back to query form