NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of May 10, 2024.

Search: Author = N.Madden

Found 6 matches.

Back to query form



2013AR05      Astropart.Phys. 49, 52 (2013)

T.Aramaki, S.K.Chan, W.W.Craig, L.Fabris, F.Gahbauer, C.J.Hailey, J.E.Koglin, N.Madden, K.Mori, H.T.Yu, K.P.Ziock

A measurement of atomic X-ray yields in exotic atoms and implications for an antideuteron-based dark matter search

NUCLEAR REACTIONS Al, Fe, S, Cl, Br, Au(p-bar, X), E=1 GeV; measured reaction products, X-rays; deduced yields. Comparison with calculations and available data.

doi: 10.1016/j.astropartphys.2013.08.003
Citations: PlumX Metrics


1996PE30      Nucl.Instrum.Methods Phys.Res. A381, 97 (1996)

R.H.Pehl, E.L.Hull, N.W.Madden, J.Xing, D.L.Friesel

Gamma-Ray Escape Peak Characteristics of Radiation-Damaged Reverse-Electrode Germanium Coaxial Detectors

RADIOACTIVITY 60Co(β-); measured Eγ, Iγ; deduced response vs position in radiation-damaged coaxial Ge detectors.

doi: 10.1016/0168-9002(96)00648-1
Citations: PlumX Metrics


1995KW02      Nucl.Instrum.Methods Phys.Res. A360, 571 (1995)

K.Kwiatkowski, D.S.Bracken, K.B.Morley, J.Brzychczyk, E.Renshaw Foxford, K.Komisarcik, V.E.Viola, N.R.Yoder, J.Dorsett, J.Poehlman, N.Madden, J.Ottarson

The Indiana Silicon Sphere 4π Charged-Particle Detector Array

NUCLEAR REACTIONS 197Au, Ag(3He, X), E=1.8-4.8 GeV; measured intermediate mass fragment multiplicity, charge, thermal energy, distributions. Silicon sphere 4π charged particle detector array.

doi: 10.1016/0168-9002(95)00011-9
Citations: PlumX Metrics


1994KW04      Nucl.Instrum.Methods Phys.Res. A353, 212 (1994)

K.Kwiatkowski, A.Alexander, D.S.Bracken, J.Brzychczyk, J.Dorsett, R.Ensman, E.Renshaw Foxford, T.Hamilton, K.Komisarcik, K.N.McDonald, K.B.Morley, J.Poehlman, C.Powell, V.E.Viola, N.R.Yoder, J.Ottarson, N.Madden

A 4π Charged-Particle Detector Array for Light-Ion-Induced Nuclear Fragmentation Studies

NUCLEAR REACTIONS Ag, 197Au(3He, X), E=1.8-4.8 GeV; measured particle spectra; deduced He, Li fragments separation, detector characteristics. 4π charged particle detector array.

doi: 10.1016/0168-9002(94)91640-3
Citations: PlumX Metrics


1994LE36      Nucl.Instrum.Methods Phys.Res. A345, 492 (1994)

M.LeGros, E.Silver, N.Madden, J.Beeman, F.Goulding, D.Landis, E.Haller

Microcalorimeters for Broad Band High Resolution X-Ray Spectral Analysis

NUCLEAR REACTIONS Ti, Ag, 27Al(X, X), E=radioactive source; measured fluorescence spectra. Large area microcalorimeter for broad band high resolution X-ray spectral analysis.

ATOMIC PHYSICS Ti, Ag, 27Al(X, X), E=radioactive source; measured fluorescence spectra. Large area microcalorimeter for broad band high resolution X-ray spectral analysis.

RADIOACTIVITY 55Fe(EC); measured X-ray spectra. Large area microcalorimeter for broad band high resolution X-ray spectral analysis.

doi: 10.1016/0168-9002(94)90504-5
Citations: PlumX Metrics


1986CA07      Phys.Rev. D33, 2737 (1986)

D.O.Caldwell, R.M.Eisberg, D.M.Grumm, D.L.Hale, M.S.Witherell, F.S.Goulding, D.A.Landis, N.W.Madden, D.F.Malone, R.H.Pehl, A.R.Smith

Half-Life Limits on the Zero-Neutrino and Two-Neutrino Double-β Decay of 76Ge

RADIOACTIVITY 76Ge(2β); measured zero-, two-neutrino double β-decay T1/2 lower limit.

doi: 10.1103/PhysRevD.33.2737
Citations: PlumX Metrics


Back to query form


Note: The following list of authors and aliases matches the search parameter N.Madden: , N.W.MADDEN