Abstract
The technique and results of a precise measurement of the 14C beta spectrum in the energy range 10–160 keV by using a wall-less proportional counter are presented. The results of analysis and the inclusion of possible factors that distort the spectrum in the calculation of the detector response function are reported. Considerable deviations from the distribution expected for an allowed transition are found.
Similar content being viewed by others
References
M. Morita, Beta Decay and Muon Capture (Benjamin, Reading, 1973), p. 33.
F. P. Calaprice and B. R. Holstein, Nucl. Phys. A 273, 301 (1976).
A. García and B. A. Brown, Phys. Rev. C 52, 3416 (1995).
H. Behrens, H. Genz, M. Conze, et al., Ann. Phys. (N.Y.) 115, 276 (1978).
C. S. Cook, L. M. Langer, and H. C. Price, Phys. Rev. 74, 548 (1948).
S. D. Warshaw, Phys. Rev. 80, 111 (1950).
J. Angus, A. L. Cockroft, and S. C. Curran, Philos. Mag. 40, 552 (1949).
J. P. Mize and D. J. Zaffarano, Phys. Rev. 91, 210 (1953).
L. Feldman and C. S. Wu, Phys. Rev. 75, 1286 (1949).
C. S. Wu and M. Schwarzschild, Phys. Rev. 91, 483 (1953).
A. Moljk and S. C. Curran, Phys. Rev. 96, 395 (1954).
H. J. Rose, O. Hausser, and E. K. Warburton, Rev. Mod. Phys. 40, 591 (1968).
P. F. Zweifel, Phys. Rev. 95, 112 (1954).
H. Genz, G. Kuhner, A. Richter, and H. Behrens, Z. Phys. A 341, 9 (1991).
F. E. Weitfeldt, E. B. Norman, Y. D. Chan, et al., Phys. Rev. C 52, 1028 (1995).
E. Commins, private communication.
B. Sur, E. B. Norman, K. T. Lesko, et al., Phys. Rev. Lett. 66, 2444 (1991).
G. Alimonti, G. Angloher, C. Arpesell, et al., Phys. Lett. B 422, 349 (1998).
G. S. Sidhu and J. B. Gerhart, Phys. Rev. 148, 1024 (1966).
H. Genz, A. Richter, B. M. Schmitz, and H. Behrens, Nucl. Phys. A 267, 13 (1976).
Ch. Sonntag, H. Rebel, B. Ribbat, et al., Lett. Nuovo Cimento 4, 717 (1970).
V. V. Kuzminov, N. Ya. Osetrova, and A. M. Shalagin, Prib. Tekh. Éksp. 39, 654 (1996) [Instrum. Exp. Tech. 5, 38 (1996)].
GEANT3, Detector Description and Simulation Tool (CERN, Geneva, 1994).
J. Szarka, P. Povinec, and V. Hlinka, Nucl. Instrum. Methods 164, 463 (1979).
Author information
Authors and Affiliations
Additional information
From Yadernaya Fizika, Vol. 63, No. 7, 2000, pp. 1365–1369.
Original English Text Copyright © 2000 by Kuzminov, Osetrova.
This article was submitted by the authors in English.
Rights and permissions
About this article
Cite this article
Kuzminov, V.V., Osetrova, N.J. Precise measurement of 14C beta spectrum by using a wall-less proportional counter. Phys. Atom. Nuclei 63, 1292–1296 (2000). https://doi.org/10.1134/1.855786
Issue Date:
DOI: https://doi.org/10.1134/1.855786