NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 27, 2024.

Search: Author = T.Ludziejewski

Found 10 matches.

Back to query form



1997MO37      Nucl.Instrum.Methods Phys.Res. A385, 123 (1997)

M.Moszynski, D.Wolski, T.Ludziejewski, M.Kapusta, A.Lempicki, C.Brecher, D.Wisniewski, A.J.Wojtowicz

Properties of the New LuAP:Ce scintillator

RADIOACTIVITY 137Cs, 60Co(β-), 22Na(β+), 241Am(α); measured γ-, α-spectra; deduced detector properties. LuAP:Ce scintillator.

doi: 10.1016/S0168-9002(96)00875-3
Citations: PlumX Metrics


1996LU13      Phys.Rev. A54, 232 (1996)

T.Ludziejewski, P.Rymuza, Z.Sujkowski, G.Borchert, J.-Cl.Dousse, C.Rheme, M.Polasik

Electron-Impact-Induced K Plus M Shell Ionization in Solid Targets of Medium-Z Elements Studied by Means of High-Resolution X-Ray Spectroscopy

ATOMIC PHYSICS Zr, 93Nb, Mo, Pd(e, X), E=150, 300 keV; measured X-ray spectra; deduced total K-, M-shell ionization probabilities vs target Z. Multi-configuration Dirac-Fock calculations.

doi: 10.1103/PhysRevA.54.232
Citations: PlumX Metrics


1996MO27      Nucl.Instrum.Methods Phys.Res. A372, 51 (1996)

M.Moszynski, T.Ludziejewski, D.Wolski, W.Klamra, V.V.Avdeichikov

Timing Properties of GSO, LSO and Other Ce Doped Scintillators

RADIOACTIVITY 241Am(α); 137Cs(β-); 60Co(β-); 22Na(β+), (EC); measured α-, γ-spectra time distribution; deduced GSO, LSO, other Ce doped scintillators timing properties.

doi: 10.1016/0168-9002(95)01244-3
Citations: PlumX Metrics


1995BO36      Phys.Rev. A51, 3650 (1995)

B.Boschung, J.-Cl.Dousse, B.Galley, Ch.Herren, J.Hoszowska, J.Kern, Ch.Rheme, Z.Halabuka, T.Ludziejewski, P.Rymuza, Z.Sujkowski, M.Polasik

Kα Hypersatellite Lines of Medium-Mass Atoms Induced by 100-MeV 4He2+ Ions

NUCLEAR REACTIONS Zr, Mo, Pd(α, X), E=100 MeV; measured X-ray spectra; deduced double K-shell ionization σ. Model comparison.

ATOMIC PHYSICS Zr, Mo, Pd(α, X), E=100 MeV; measured X-ray spectra; deduced double K-shell ionization σ. Model comparison.

doi: 10.1103/PhysRevA.51.3650
Citations: PlumX Metrics


1995BO44      Phys.Rev. A52, 3889 (1995)

B.Boschung, M.W.Carlen, J.-Cl.Dousse, B.Galley, Ch.Herren, J.Hoszowska, J.Kern, Ch.Rheme, T.Ludziejewski, P.Rymuza, Z.Sujkowski, Z.Halabuka

Probabilities for L-Shell Ionization in Intermediate-Velocity Collisions of Medium-Mass Elements with 4He2+ Ions

NUCLEAR REACTIONS Zr, Mo, Pd, Pr(α, X), E=28-100 MeV; measured X-ray spectra; deduced L-shell ionization probabilities. High resolution transmission curved crystal spectrometer.

ATOMIC PHYSICS Zr, Ho, Pd, Pr(α, X), E=28-100 MeV; measured X-ray spectra; deduced L-shell ionization probabilities. High resolution transmission curved crystal spectrometer.

doi: 10.1103/PhysRevA.52.3889
Citations: PlumX Metrics


1995LU24      Phys.Rev. A52, 2791 (1995)

T.Ludziejewski, P.Rymuza, Z.Sujkowski, B.Boschung, J.-Cl.Dousse, B.Galley, Z.Halabuka, Ch.Herren, J.Hoszowska, J.Kern, Ch.Rheme, M.Polasik

High-Resolution Study of the Kβ2 X-Ray Spectra Induced by Proton and Photon Impact on Zr, Mo, and Pd Targets

NUCLEAR REACTIONS Zr, Mo, Pd(γ, X), E ≤ 25 keV; Zr, Mo, Pd(p, X), E=16, 25, 45 MeV; measured X-ray spectra; deduced sub-shell ionization probabilities. Transmission bent crystal spectrometer.

ATOMIC PHYSICS Zr, Mo, Pd(γ, X), E ≤ 25 keV; Zr, Mo, Pd(p, X), E=16, 25, 45 MeV; measured X-ray spectra; deduced sub-shell ionization probabilities. Transmission bent crystal spectrometer.

doi: 10.1103/PhysRevA.52.2791
Citations: PlumX Metrics


1995WO03      Nucl.Instrum.Methods Phys.Res. A360, 584 (1995)

D.Wolski, M.Moszynski, T.Ludziejewski, A.Johnson, W.Klamra, O.Skeppstedt

Comparison of n-γ Discrimination by Zero-Crossing and Digital Charge Comparison Methods

doi: 10.1016/0168-9002(95)00037-2
Citations: PlumX Metrics


1994LU09      Acta Phys.Pol. B25, 699 (1994)

T.Ludziejewski, P.Rymuza, Z.Sujkowski, D.Anagnostopoulos, G.Borchert, M.Carlen, J.-Cl.Dousse, J.Hoszowska, J.Kern, Ch.Rheme

L-Shell Ionization Probabilities in Near Central Heavy Ion-Atom Collisions

NUCLEAR REACTIONS U(Ne, X), E=500 MeV; Pd(O, X), E=86.4 MeV; Tb(Ne, X), E=300 MeV; Tb(N, X), E=210 MeV; Mo(O, X), E=88 MeV; Nd(N, X), E=210 MeV; Ta(N, X), E=350 MeV; La(N, X), E=403 MeV; measured X-ray yield distributions; deduced L-shell ionization probabilities.

ATOMIC PHYSICS U(Ne, X), E=500 MeV; Pd(O, X), E=86.4 MeV; Tb(Ne, X), E=300 MeV; Tb(N, X), E=210 MeV; Mo(O, X), E=88 MeV; Nd(N, X), E=210 MeV; Ta(N, X), E=350 MeV; La(N, X), E=403 MeV; measured X-ray yield distributions; deduced L-shell ionization probabilities.


1994MO46      Nucl.Instrum.Methods Phys.Res. A345, 461 (1994)

M.Moszynski, T.Ludziejewski, D.Wolski, W.Klamra, L.O.Norlin

Properties of the YAG:Ce scintillator

RADIOACTIVITY 137Cs(β-); 60Co(β-); measured Eγ, Iγ, time spectra. 241Am(α); measured Eα, Iα, time spectra; deduced YAG:Ce scintillator properties.

doi: 10.1016/0168-9002(94)90500-2
Citations: PlumX Metrics


1993MO29      Nucl.Instrum.Methods Phys.Res. A336, 587 (1993)

M.Moszynski, D.Wolski, T.Ludziejewski, S.E.Arnell, O.Skeppstedt, W.Klamra

Particle Identification by Digital Charge Comparison Method Applied to CsI(Tl) Crystal Coupled to Photodiode

RADIOACTIVITY 137Cs(β-); measured Eγ, Iγ. 232Th(α); measured α-spectra; deduced device particle identification capabilities. Digital charge comparison method, CsI(Tl)-photodiode assembly, proton spectra studied.

doi: 10.1016/0168-9002(93)91267-Q
Citations: PlumX Metrics


Back to query form