1996RE26      Nucl.Instrum.Methods Phys.Res. A380, 312 (1996)

R.Redus, M.Squillante, J.Lund

Electronics for High Resolution Spectroscopy with Compound Semiconductors

RADIOACTIVITY 137Cs(β-); 57Co(EC); measured spectra; deduced detector energy resolution characteristics. Spectrometer using multiple CdTe radiation detectors.

doi: 10.1016/S0168-9002(96)00307-5
Citations: PlumX Metrics


1996SH26      Nucl.Instrum.Methods Phys.Res. A380, 266 (1996)

K.S.Shah, F.Olschner, L.P.Moy, P.Bennett, M.Misra, J.Zhang, M.R.Squillante, J.C.Lund

Lead Iodide X-Ray Detection Systems

RADIOACTIVITY 55Fe(EC); 241Am(α); measured X-ray, γ-ray spectra; deduced detector resolution related features. Room temperature (PbI2) X-ray detectors.

doi: 10.1016/S0168-9002(96)00346-4
Citations: PlumX Metrics


1996SQ01      Nucl.Instrum.Methods Phys.Res. A380, 160 (1996)

M.R.Squillante, G.Entine

Novel Concepts in X-Ray and γ-Ray Detection using Compound Semiconductors

RADIOACTIVITY 57Co(EC); 137Cs(β-); measured Eγ, Iγ. Compound semiconductors.

doi: 10.1016/S0168-9002(96)00301-4
Citations: PlumX Metrics


1994FA24      Nucl.Instrum.Methods Phys.Res. A353, 176 (1994)

R.Farrell, K.Vanderpuye, L.Cirignano, M.R.Squillante, G.Entine

Radiation Detection Performance of Very High Gain Avalanche Photodiodes

RADIOACTIVITY 57Co(EC); 207Bi(EC), (β+); 90Sr(β-); measured β-spectra. 55Fe(EC); measured X-ray spectra; deduced devices performance characteristics as radiation detectors. Large area Si avalanche photodiodes.

doi: 10.1016/0168-9002(94)91632-2
Citations: PlumX Metrics


1994RE26      Nucl.Instrum.Methods Phys.Res. A353, 59 (1994)

R.Redus, M.Squillante, J.Lund, L.Cirignano, P.Waer, J.Pantazis, A.Huber

High Resolution CdTe Detector Systems

RADIOACTIVITY 137Cs(β-); analyzed data; deduced CdTe detector systems resolution, other features.

doi: 10.1016/0168-9002(94)91602-0
Citations: PlumX Metrics


1994SH47      Nucl.Instrum.Methods Phys.Res. A353, 85 (1994)

K.S.Shah, J.C.Lund, F.Olschner, P.Bennett, J.Zhang, L.P.Moy, M.R.Squillante

Electronic Noise in Lead Iodide X-Ray Detectors

RADIOACTIVITY 55Fe(EC); 241Am(α); measured X-ray spectra; deduced lead iodide detector electronic noise, related features.

doi: 10.1016/0168-9002(94)91608-X
Citations: PlumX Metrics


1992SH25      Nucl.Instrum.Methods Phys.Res. A322, 509 (1992)

K.S.Shah, L.P.Moy, J.Zhang, F.Olschner, J.C.Lund, M.R.Squillante

HgBr(x)I(2-x) Photodetectors for Use in Scintillation Spectroscopy

RADIOACTIVITY 241Am(α); measured spectra; deduced photodetectors performance limiting dominant factors. High quality HgBr(x)I(2-x) photodetectors coupled to CsI(Na) scintillator.

doi: 10.1016/0168-9002(92)91223-V
Citations: PlumX Metrics


1990FA15      Nucl.Instrum.Methods Phys.Res. A288, 137 (1990)

R.Farrell, F.Olschner, E.Frederick, L.McConchie, K.Vanderpuye, M.R.Squillante, G.Entine

Large Area Silicon Avalanche Photodiodes for Scintillation Detectors

RADIOACTIVITY 137Cs; measured Eγ, Iγ. Large area Si avalanche photodiodes as optical detectors.

doi: 10.1016/0168-9002(90)90478-O