NSR Query Results
Output year order : Descending NSR database version of April 27, 2024. Search: Author = J.Bouchard Found 12 matches. 2019BO14 Appl.Radiat.Isot. 153, 108826 (2019) C.Bobin, J.Bouchard, V.Chiste, S.M.Collins, P.Dryak, A.Fenwick, J.Keightley, M.-C.Lepy, V.Lourenco, A.P.Robinson, J.Sochorova, J.Solc, C.Thiam Activity measurements and determination of nuclear decay data of 166Ho in the MRT Dosimetry project RADIOACTIVITY 166Ho(β-); measured decay products, Eγ, Iγ, X-rays, Eβ, Iβ; deduced T1/2.
doi: 10.1016/j.apradiso.2019.108826
2007BO51 Appl.Radiat.Isot. 65, 757 (2007) C.Bobin, J.Bouchard, C.Hamon, M.G.Iroulart, J.Plagnard Standardization of 67Ga using a 4π(LS)β-γ anti-coincidence system RADIOACTIVITY 67Ga(EC); measured decay products, Eγ, Iγ, absolute Iγ, γ-emission probabilities using 4π(LS)β-γ-anti-coincidence system at the LNE-LNHB facility.
doi: 10.1016/j.apradiso.2007.01.003
2006BO01 Appl.Radiat.Isot. 64, 124 (2006) A 4π(LS)β-γ coincidence system using a TDCR apparatus in the β channel RADIOACTIVITY 54Mn, 65Zn(EC); measured βγ-coin. Triple to double coincidence ratio method.
doi: 10.1016/j.apradiso.2005.06.008
2005AM01 Appl.Radiat.Isot. 62, 11 (2005) M.N.Amiot, J.Bouchard, M.M.Be, J.A.Adamo Half-life determination of 88Y and 89Sr RADIOACTIVITY 88Y(EC); 89Sr(β-); measured T1/2. Comparison with previous results.
doi: 10.1016/j.apradiso.2004.06.002
1996BO18 Nucl.Instrum.Methods Phys.Res. A369, 380 (1996) The Pulse Mixing Method Applied to the Activity Measurement of 85Sr RADIOACTIVITY 85Sr(EC); measured activity. 4π βγ-coincidence system.
doi: 10.1016/S0168-9002(96)80013-1
1994CA40 Nucl.Instrum.Methods Phys.Res. A339, 339 (1994) P.Cassette, J.Bouchard, B.Chauvenet Standardization of Iodine-129 by the TDCR Liquid Scintillation Method and 4π β-γ Coincidence Counting RADIOACTIVITY 129I(β-); measured βγ-coin; deduced source standardization. 4π βγ-coincidence, TDCR liquid scintillation method.
doi: 10.1016/0168-9002(94)91828-7
1994CH56 Nucl.Instrum.Methods Phys.Res. A339, 394 (1994) Correction of the Isomeric-State Effect using the Double Dead-Time Method in the Activity Measurement of 75Se RADIOACTIVITY 75Se(EC); measured βγ-coin; deduced isomeric state related correction factor to activity. 4π gas filled proportional counter plus NaI(Tl) detector.
doi: 10.1016/0168-9002(94)91838-4
1992CO10 Nucl.Instrum.Methods Phys.Res. A312, 24 (1992) N.Coursol, N.Coron, D.Masse, H.Stroke, J.W.Zhou, P.de Marcillac, J.Leblanc, G.Artzner, G.Dambier, J.Bouchard, G.Jegoudez, J.P.Lepeltier, G.Nollez, C.Golbach, J.-L.Picolo Performance and Applications of Cooled Composite Bolometers in the Field of Ionizing Radiation Metrology RADIOACTIVITY 241Am(α); measured photon, α-spectra. 239Pu, 244Cm(α); measured α-spectra. 109Cd; measured I(ce); deduced instrument resolution. Cooled composite bolometers.
doi: 10.1016/0168-9002(92)90121-J
1987CH01 Appl.Radiat.Isot. 38, 41 (1987) B.Chauvenet, J.Bouchard, R.Vatin Calculation of Extrapolation Curves in the 4πβ-γ Coincidence Method RADIOACTIVITY 51Cr, 133Ba, 195Au, 201Tl(EC); calculated activities; calculated extrapolated activity values, EC probabilities, correction factors. 4πβ-γ coincidence method.
doi: 10.1016/0883-2889(87)90234-6
1987CH20 Appl.Radiat.Isot. 38, 799 (1987) B.Chauvenet, J.Bouchard, R.Vatin Theory and Capabilities of a 4πβ-γ Coincidence System with Cumulative Dead Times RADIOACTIVITY 60Co(β-); measured βγ-coin. Cumulative dead time 4π βγ-coincidence system.
doi: 10.1016/0883-2889(87)90176-6
1986RE12 Int.J.Appl.Radiat.Isotop. 37, 973 (1986) D.Reher, H.H.Hansen, R.Vaninbroukx, M.J.Woods, C.E.Grant, S.E.M.Lucas, J.Bouchard, J.Morel, R.Vatin The Decay of 47Sc RADIOACTIVITY 47Sc(β-); measured Eβ, Iβ, Eγ, Iγ, I(ce); deduced T1/2, γ-emission probabilities, β-endpoint energies. 47Ti levels deduced ICC, Iβ.
doi: 10.1016/0883-2889(86)90249-2
1978MA06 Z.Phys. A284, 389 (1978) P.Magnier, J.Bouchard, M.Blondel, J.Legrand, J.P.Perolat, R.Vatin Precise Measurement of the X(k) Emission Rate Following the Electron Capture-Decay of 54Mn-Fluorescence Yield Omega(k) of Cr RADIOACTIVITY 54Mn; measured K X-ray emission rate. 54Cr deduced fluorescence yield.
doi: 10.1007/BF01422106
Back to query form |