NSR Query Results
Output year order : Descending NSR database version of April 27, 2024. Search: Author = H.Stolzenberg Found 7 matches. 1999AM05 Nucl.Phys. A651, 3 (1999) F.Ames, G.Audi, D.Beck, G.Bollen, M.de Saint Simon, R.Jertz, H.-J.Kluge, A.Kohl, M.Konig, D.Lunney, I.Martel, R.B.Moore, T.Otto, Z.Patyk, H.Raimbault-Hartmann, G.Rouleau, G.Savard, E.Schark, S.Schwarz, L.Schweikhard, H.Stolzenberg, J.Szerypo, and the ISOLDE Collaboration High-Accuracy Mass Determination of Unstable Cesium and Barium Isotopes ATOMIC MASSES 117,118,119,120,122,123,124,125,126,127,128,129,130,131,132,133,134,135,136,137,138,139,140,141,142Cs, 123,124,125,126,127,128,131,138,139,140,141,142,143,144Ba; measured masses. Online mass spectrometry, Penning trap, least-squares adjustment of data. Macroscopic-microscopic model calculations.
doi: 10.1016/S0375-9474(99)00111-6
1996BO47 Nucl.Instrum.Methods Phys.Res. A368, 675 (1996) G.Bollen, S.Becker, H.-J.Kluge, M.Konig, R.B.Moore, T.Otto, H.Raimbault-Hartmann, G.Savard, L.Schweikhard, H.Stolzenberg, and the ISOLDE Collaboration ISOLTRAP: A tandem Penning trap system for accurate on-line mass determination of short-lived isotopes
doi: 10.1016/0168-9002(95)00561-7
1994OT01 Nucl.Phys. A567, 281 (1994) T.Otto, G.Bollen, G.Savard, L.Schweikhard, H.Stolzenberg, G.Audi, R.B.Moore, G.Rouleau, J.Szerypo, Z.Patyk, and the ISOLDE Collaboration Penning-Trap Mass Measurements of Neutron-Deficient Rb abd Sr Isotopes ATOMIC MASSES 75,76,77,78,79,80,81,82,83,84,85,86,87Rb, 78,79,80,81,82,83,87Sr; measured masses. Penning-trap mass spectrometer (on-line), least-squares adjustment of data. Macroscopic-microscopic mass calculations.
doi: 10.1016/0375-9474(94)90149-X
1992BO28 J.Mod.Opt. 39, 257 (1992) G.Bollen, J.-J.Kluge, Th.Otto, G.Savard, L.Schweikhard, H.Stolzenberg, G.Audi, R.B.Moore, G.Rouleau, and the ISOLDE Collaboration Mass Determination of Francium and Radium Isotopes by a Penning Trap Mass Spectrometer ATOMIC MASSES 209,210,211,212,221,222Fr, 226,230Ra; measured mass. Tandem Penning trap mass spectrometer.
doi: 10.1080/09500349214550261
1992BO31 Phys.Rev. C46, R2140 (1992) G.Bollen, H.-J.Kluge, M.Konig, T.Otto, G.Savard, H.Stolzenberg, R.B.Moore, G.Rouleau, G.Audi, and the ISOLDE Collaboration Resolution of Nuclear Ground and Isomeric States by a Penning Trap Mass Spectrometer ATOMIC MASSES 78m,78g,84m,84gRb; measured cyclotron frequency; deduced masses, excitation energy. Penning trap mass spectrometer, on-line isotope separation.
doi: 10.1103/PhysRevC.46.R2140
1990ST25 Phys.Rev.Lett. 65, 3104 (1990) H.Stolzenberg, St.Becker, G.Bollen, F.Kern, H.-J.Kluge, Th.Otto, G.Savard, L.Schweikhard, G.Audi, R.B.Moore Accurate Mass Determination of Short-Lived Isotopes by a Tandem Penning-Trap Mass Spectrometer ATOMIC MASSES 118,119,120,121,122,123,124,125,126,127,128,129,130,131,132,133,134,135,135,137Cs; measured masses. Tandem Penning-trap mass spectrometer, comparison with other methods.
doi: 10.1103/PhysRevLett.65.3104
1987BO59 Hyperfine Interactions 38, 793 (1987) G.Bollen, P.Dabkiewicz, P.Egelhof, T.Hilberath, H.Kalinowsky, F.Kern, H.Schnatz, L.Schweikhard, H.Stolzenberg, R.B.Moore, H.-J.Kluge, G.M.Temmer, G.Ulm, and the ISOLDE Collaboration First Absolute Mass Measurements of Short-Lived Isotopes RADIOACTIVITY 77Rb(β+), (EC); measured T1/2. On-line mass separator, Penning trap ion confinement. ATOMIC MASSES 39K, 85,87,77Rb, 133Cs; analyzed data; deduced mass measurement accuracies.
doi: 10.1007/BF02394875
Back to query form |