2022NO06      Phys.Rev. C 105, 055501 (2022)

P.Novella, M.Sorel, A.Uson, C.Adams, H.Almazan, V.Alvarez, B.Aparicio, A.I.Aranburu, L.Arazi, I.J.Arnquist, S.Ayet, C.D.R.Azevedo, K.Bailey, F.Ballester, J.M.Benlloch-Rodriguez, F.I.G.M.Borges, S.Bounasser, N.Byrnes, S.Carcel, J.V.Carrion, S.Cebrian, E.Church, C.A.N.Conde, T.Contreras, F.P.Cossio, A.A.Denisenko, G.Diaz, J.Diaz, T.Dickel, J.Escada, R.Esteve, A.Fahs, R.Felkai, L.M.P.Fernandes, P.Ferrario, A.L.Ferreira, F.W.Foss, E.D.C.Freitas, Z.Freixa, J.Generowicz, A.Goldschmidt, J.J.Gomez-Cadenas, R.Gonzalez, D.Gonzalez-Diaz, R.Guenette, R.M.Gutierrez, J.Haefner, K.Hafidi, J.Hauptman, C.A.O.Henriques, J.A.Hernando Morata, P.Herrero-Gomez, V.Herrero, J.Ho, Y.Ifergan, B.J.P.Jones, M.Kekic, L.Labarga, A.Laing, L.Larizgoitia, P.Lebrun, D.Lopez Gutierrez, N.Lopez-March, M.Losada, R.D.P.Mano, J.Martin-Albo, A.Martinez, G.Martinez-Lema, M.Martinez-Vara, A.D.McDonald, Z.E.Meziani, K.Mistry, F.Monrabal, C.M.B.Monteiro, F.J.Mora, J.Munoz Vidal, K.Navarro, D.R.Nygren, E.Oblak, M.Odriozola-Gimeno, B.Palmeiro, A.Para, J.Perez, M.Querol, A.Raymond, A.B.Redwine, J.Renner, L.Ripoll, I.Rivilla, Y.Rodriguez Garcia, J.Rodriguez, C.Rogero, L.Rogers, B.Romeo, C.Romo-Luque, F.P.Santos, J.M.F.dos Santos, A.Simon, C.Stanford, J.M.R.Teixeira, P.Thapa, J.F.Toledo, J.Torrent, J.F.C.A.Veloso, T.T.Vuong, R.Webb, J.T.White, K.Woodruff, N.Yahlali, for the NEXT Collaboration

Measurement of the 136Xe two-neutrino double-β-decay half-life via direct background subtraction in NEXT

RADIOACTIVITY 136Xe(2β-); measured Eβ, Iβ, ββ-coin; deduced event rate, T1/2 of two-neutrino double-β-decay. NEXT-White time-projection chamber loaded with Xenon operated at Laboratorio Subterraneo de Canfranc. Data from 2016-021 campaign.

doi: 10.1103/PhysRevC.105.055501
Citations: PlumX Metrics

Data from this article have been entered in the XUNDL database. For more information, click here.


2012DO13      Nucl.Instrum.Methods Phys.Res. B293, 16 (2012)

S.J.C.do Carmo, F.I.G.M.Borges, A.M.F.Trindade, C.A.N.Conde

K X-ray production cross sections in aluminium for 15, 20 and 25 keV protons

NUCLEAR REACTIONS Al(p, X), E=15, 20, 25 keV; measured reaction products, X-rays; deduced X-ray thick target yields, production σ.

doi: 10.1016/j.nimb.2012.09.019
Citations: PlumX Metrics


2000PO33      Hyperfine Interactions 127, 161 (2000)

R.Pohl, F.Biraben, C.A.N.Conde, C.Donche-Gay, T.W.Hansch, F.J.Hartmann, P.Hauser, V.W.Hughes, O.Huot, P.Indelicato, P.Knowles, F.Kottmann, Y.-W.Liu, F.Mulhauser, F.Nez, C.Petitjean, P.Rabinowitz, J.M.F.dos Santos, L.A.Schaller, H.Schneuwly, W.Schott, L.M.Simons, D.Taqqu, F.Trehin, J.F.C.A.Veloso

Experiment to measure the Lamb shift in muonic hydrogen

ATOMIC PHYSICS, Mesic-atoms 1H(μ-, X), E=low; measured muonic atoms kinetic energy distribution; deduced metastable state population. Application to proposed experiment discussed.

doi: 10.1023/A:1012679114531
Citations: PlumX Metrics


1996BO51      Nucl.Instrum.Methods Phys.Res. A381, 91 (1996)

F.I.G.M.Borges, C.A.N.Conde

Experimental W-Values in Gaseous Xe, Kr and Ar for Low Energy X-Rays

doi: 10.1016/0168-9002(96)00739-5
Citations: PlumX Metrics


1994DO24      Nucl.Instrum.Methods Phys.Res. A337, 427 (1994)

J.M.F.dos Santos, A.C.S.S.M.Bento, C.A.N.Conde

The Performance of the Curved Grid Gas Proportional Scintillation Counter in X-Ray Spectrometry

RADIOACTIVITY 55Fe(EC); measured X-ray spectra; deduced detector energy resolution characteristics. Curved grid gas proportional scintillation counter, other activation techniques used.

doi: 10.1016/0168-9002(94)91112-6
Citations: PlumX Metrics


1994DO33      Nucl.Instrum.Methods Phys.Res. A353, 195 (1994)

J.M.F.dos Santos, J.F.C.A.Veloso, R.E.Morgado, C.A.N.Conde

The Performance of a Compact gas Proportional Scintillation Counter for Hard X-Ray Spectrometry

RADIOACTIVITY 241Am(α); 109Cd(EC); measured α-, X-ray spectra, pulse height distributions. Compact, room temperature xenon gas proportional scintillation counter.

doi: 10.1016/0168-9002(94)91636-5
Citations: PlumX Metrics


1993DO09      Nucl.Instrum.Methods Phys.Res. A324, 611 (1993)

J.M.F.dos Santos, C.A.N.Conde, A.C.S.S.M.Bento

The Energy Linearity of Gaseous Xenon Radiation Detectors for X-Rays with Energies between 2 and 60 keV: Experimental results

NUCLEAR REACTIONS I, Ba, La, Dy, Tm, Ta, K, Ca, Ti, V, Cr, 55Mn, Fe(X, X), E=radioactive; measured primary electron average number; deduced discontinuity near L-shell threshold of detector energy linearity. Gaseous xenon radiation detectors, 244Cm as X-ray, α-source.

ATOMIC PHYSICS I, Ba, La, Dy, Tm, Ta, K, Ca, Ti, V, Cr, 55Mn, Fe(X, X), E=radioactive; measured primary electron average number; deduced discontinuity near L-shell threshold of detector energy linearity. Gaseous xenon radiation detectors, 244Cm as X-ray, α-source.

doi: 10.1016/0168-9002(93)91068-X
Citations: PlumX Metrics