26MG 26AL EC DECAY (6.3460 S) 2012FI06 16NDS 201604
26MG H TYP=FUL$AUT=M.S. Basunia and A.M. Hurst$CIT=NDS 134, 1 (2016)$
26MG2 H CUT=1-Feb-2016$
26MG C Others: 2011Fi01,1989Sk02,1987Wi06,1983Va01,1969De27
26MG c 2012Fi06,2011Fi01: Proton beam, E=500 MeV, bombarded SiC (thickness
26MG2C 14.35 g/cm{+2}) target. TRIUMF Resonant Ionization Laser Ion Source use
26MG2c to ionize aluminum isotopes selectively. A 30-keV ion beam of separated
26MG3c products (A=26) was implanted into a aluminized mylar tape and allowed
26MG4c to cool for 26-34 seconds to reduce the amount of {+26}Na. The
26MG5c detection system was a 4|p continuous-flow gas proportional counter.
26MG6c The half-life of the 228-keV, 0+ isomeric state was measured from the
26MG7c decay curve using maximum likelihood method.
26AL P 228.305 13 0+ 6.3460 S 8 4004.43 6
26MG N 1.0 1.0
26MG L 0 0+ STABLE
26MG E 99.9176 9 0.0824 9 3.48281 6 100
26MGS E EAV=1439.58$CK=0.0007540$CL=6.561E-5$CM+=4.226E-6