171PT    171PT IT DECAY                2010SC02                  18NDS    201808
171PT  H TYP=FUL$AUT=CORAL M. BAGLIN, E.A. MCCUTCHAN$CIT=NDS 151, 334 (2018)$
171PT2 H CUT=30-Jun-2018$
171PT C  13/2+ ISOMER PRODUCED USING 96RU(78KR,2PNG), E=348 MeV;
171PT2C  RECOILS SEPARATED BY ^RITU MASS SEPARATOR; MULTI-WIRE PROPORTIONAL
171PT3C  COUNTER; RECOILS IMPLANTED IN DOUBLE-SIDED SI STRIP DETECTORS OF ^GREAT
171PT4C  SPECTROMETER AT ^RITU FOCAL PLANE; ONE PLANAR AND 3 CLOVER Ge
171PT5C  DETECTORS AT FOCAL PLANE; ^JUROGAM array (43 escape-suppressed
171PT6C  ^EUROGAM phase-^I and ^GASP type HPGe detectors) FOR PROMPT G DETECTION
171PT7C  AT TARGET POSITION; recoil-isomer and recoil-(|a decay) tagging
171PT8C  techniques; MEASURED EG, IG, ce, GG COIN, ce-G COIN, G(t), ^T{-1/2} (GS
171PT9C  AND ISOMER).
171PT CG E(A)      TRANSITION OBSERVED TO be IN DELAYED COINCIDENCE WITH
171PT2CG THE 445-, 605- AND 670-KEV PROMPT G-RAYS FROM THE 96RU(78KR,2PNG)
171PT3CG REACTION.
171PT CL E         FROM EG.
171PT CL J         FROM Adopted Levels.
171PT  P 412.6     10 (13/2+)          901 NS     9
171PT  N  0.519     8          1.0
171PT CN NR        FROM %IT=100=TI(323G).
171PT PN                                                                     5
171PT  L   0.0         (7/2-)          48 MS      1
171PT2 L %A=83 3 (2010Sc02)
171PT CL T         from 2010Sc02 based on time differences between a recoil
171PT2CL implant and 171PT |a decay, correlated within 960 MS of a recoil and
171PT3CL also within 2.73 S and 8 S, respectively, of |a decay from 167OS and
171PT4CL 163W.
171PT  L 89.5       7  (9/2-)
171PT  G  89.5      7   19   3      M1                  9.15  25            AC
171PTS G KC=7.52 20$LC=1.26 4$MC=0.291 8$NC+=0.0858 24
171PTS G NC=0.0720 20$OC=0.0129 4$PC=0.000872 24
171PT CG M         FROM EKC=7.5 10 (2010SC02).
171PT  L 412.6     10  (13/2+)         901 NS     9
171PT2 L %IT=100
171PT CL T         from text and FIG. 16 of 2010Sc02, based on time difference
171PT2CL between recoil implantation IN DOUBLE-SIDED SI DETECTOR and detection
171PT3CL of 90G AND 323G IN the CLOVER AND PLANAR DETECTORS AND ce IN ^PIN
171PT4CL DIODES.  THE 4 NS UNCERTAINTY SHOWN IN FIG. 14c OF 2010SC02
171PT5CL IS PRESUMED TO be A MISPRINT; THIS PRESUMPTION WAS CONFIRMED IN AN
171PT6CL e-mail COMMUNICATION FROM ^C. SCHOLEY TO ^B. SINGH
171PT7CL on Feb 5, 2010.
171PT  G  323.1     6   100  14   M2                   0.926  15            AC
171PT CG M         FROM EKC=0.65 12, EKC/(ELC + EMC)=3.5 5 (2010Sc02).
171PTS G KC=0.717 11$LC=0.1593 25$MC=0.0384 6$NC+=0.01136 18
171PTS G NC=0.00955 15$OC=0.00170 3$PC=0.0001062 17