ADOPTED LEVELS, GAMMAS for 63Ge
Author: Jun Chen | Citation: Nucl. Data Sheets 196, 17 (2024) | Cutoff date: 30-Sep-2023
Full ENSDF file | Adopted Levels (PDF version)
Q(β-)=-13420 keV SY | S(n)= 12850 keV SY | S(p)= 2220 keV 40 | Q(α)= -2130 keV 40 | ||
Reference: 2021WA16 |
References: | |||
A | 64Se εp decay (22.6 MS) |
E(level) (keV) | XREF | Jπ(level) | T1/2(level) | E(γ) (keV) |
0 | A | (3/2-) | 153.3 ms 6 % ε = 100 % εp = ? | |
417.5 1 | A | 417.5 1 |
Additional Level Data and Comments:
E(level) | Jπ(level) | T1/2(level) | Comments |
E(level) | E(gamma) | Comments |
417.5 | 417.5 | E(γ): from 64Se εp decay (2019Ru07) |
Mass measurement: 2011Tu02
Other measurements:
1993Wi03,1993Wi18: 58Ni(78Kr,X) E=75 MeV 78Kr beam was produced from the K1200 cyclotron at NSCL. Fragments were separated with the A1200 mass separator and implanted into a Si detector telescope surrounded by two thin scintillator β detectors. Measured fragment-β(t). Deduced T1/2. See also 1991Mo10 with E=65 MeV/nucleon at NSCL.
2014Ro14: Ni(78Kr,X) E=70 MeV/nucleon 78Kr beam was produced at GANIL. Fragments selected with the LISE3 separator, identified by time-of-flight and energy loss and implanted into a set of four Si detectors (an energy loss ΔE detector, a degrader, DSSD and Si(Li)) for particles surrounded by four HPGe Clover detectors, three EXOGAM and one mini-clover Ge detector for γ rays. Measured (fragment)β and (fragment)γ correlations. Deduced T1/2.
2017Ku12: Ni(64Zn,X) E=79 MeV/nucleon 64Zn beam was produced at GANIL. Fragments were selected with the LISE3 separator, identified by time-of-flight and energy loss using silicon ΔE detector and implanted into a double-sided silicon strip detector (DSSSD) surrounded by four HPGe Clover detectors (three EXOGAM clovers and a smaller Euroball clover) for γ-ray detection. Measured implant-β correlations. Deduced T1/2.
2020Gi02: 9Be(78Kr, X) E=350 MeV/nucleon 78Kr beam was produced at RIKEN. Fragments were selected with the BigRIPS and the ZDS separators and implanted into the WAS3ABi device consisting of 3 DSSSDs. γ rays were detected with the EURICA array of Ge detectors. Measured implant-β-correlation. Deduced T1/2.
Theoretical calculations:
2021Kl02, 2019Zo02: calculated mass excess, S(p), S(2p)
2011Gu03: calculated rms radius
2001Fi23: calculated levels, J, π, widths.
1997Or04: calculated binding energy
Q-value: ΔQ(β-)=200, ΔS(n)=150 (syst,2021Wa16)
Q-value: S(2n)=29270 300 (syst), S(2p)=5150 40, Q(εp)=6960 40, Q(ε)=9630 40 (2021Wa16)