Abstract
The guided thermal neutron beam at 100 MW Dhruva research reactor facility of Bhabha Atomic Research Centre (BARC) was used to carry out prompt gamma-ray neutron activation analysis (PGNAA). The prompt k 0-factors have been determined for the isotopes of the elements H, B, K, Co, Cu, Ca, Ti, Cr, Cd, Ba, Hg and Gd with respect to 1951 keV gamma-line of 36Cl. The prompt k 0-factors for H, Cl and Cu were also measured with respect to the 1381 keV gamma-line of 49Ti. Different samples like NH4Cl, Ti metal, cobalt chloride and other stoichiometric compounds and pure metals were used for this purpose. Prompt gamma-rays were accumulated using a 22% HPGe detector connected to a PC based 8k MCA in single mode counting. The energy calibration in the range of 100–8500 keV was carried out using gamma-rays from 152Eu and 60Co, and the prompt gamma-rays from 36Cl whereas the absolute detection efficiency for this energy range was determined using 152Eu and prompt gamma-rays from 36Cl and 49Ti.
Similar content being viewed by others
References
Z. B. Alfassi,Ch. Chung (Eds), Prompt Gamma Neutron Activation Analysis, CRC Press, Boca Raton, 1995.
R. L. Paul,R. M. Lindstrom, Proc. 2nd Intern. k 0 Users Workshop, Institute Josef Stefan, Ljubljana, Slovenia, 1996, p. 54.
C. Yenozawa,H. Matsue,M. Hoshi, J. Radioanal. Nucl. Chem., 215 (1997) 81.
G. L. MolnÁr,Zs. RÉvay,R. L. Paul,R. M. Lindstrom, J. Radioanal. Nucl. Chem., 234 (1998) 21.
C. Yonezawa, Biol. Trace Elem. Res., 71/72 (1999) 407.
R. L. Paul,R. M. Lindstorm, J. Radioanal. Nucl. Chem., 243 (2000) 181.
C. Yonezawa,H. Matsue, J. Radioanal. Nucl. Chem., 244 (2000) 373.
H. Matsue,C. Yonezawa, J. Radioanal. Nucl. Chem., 245 (2000) 189.
Zs. RÉvay,G. L. MolnÁr,T. Belgya,Zs. Kasztovszky,R. B. Firestone, J. Radioanal. Nucl. Chem., 244 (2000) 383.
A. Simonits,F. De Corte,J. Hoste, J. Radioanal. Chem., 31 (1976) 467.
M. A. Lone,R. A. Leavitt,D. A. Harrison, Atomic Data Nucl. Data Tables, 26 (1981) 511.
IAEA-TECDOC-619 X-ray and Gamma-ray Standards for Detector Calibration, International Atomic Energy Agency, 1991.
J. F. A. G. Ruyl,P. M. Endt, Nucl. Phys., A407 (1983) 60.
Z. Kis,B. Fazekas,J. ÖstÖr,Zs. RÉvay,T. Belgya,G. L. MolnÁr,L. Koltay, Nucl. Instr. Meth., A 418 (1998) 374.
K. Sudarshan,A. G. C. Nair,R. N. Acharya,Y. M. Scindia,A. V. R. Reddy,S. B. Manohar,A. Goswami, Nucl. Instr. Meth., A 457 (2001) 180.
F. De Corte,A. Simonits, J. Radioanal. Nucl. Chem., 133 (1989) 43.