Development of a pulse shape discrimination circuit

https://doi.org/10.1016/0168-9002(94)90979-2Get rights and content

Abstract

A pulse shape discrimination circuit was designed and used in an experiment measuring double-differential cross sections of (n, charged particle) reaction; to identify p, α and γ. The performance of the circuit was tested. With this circuit, excellent identification of p, α and γ was obtained.

References (7)

  • J.M. Adams

    Nucl. Instr. and Meth.

    (1978)
  • M. Ahmed

    Nucl. Instr. and Meth.

    (1977)
  • R.A. Winyard

    Nucl. Instr. and Meth.

    (1971)
There are more references available in the full text version of this article.

Cited by (7)

  • The study of α/γ ratio for inorganic scintillation detectors

    1998, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Particle identification in the measurement of differential (n,x) cross sections

    1997, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
View all citing articles on Scopus