Elsevier

Nuclear Physics A

Volume 134, Issue 2, 8 September 1969, Pages 361-368
Nuclear Physics A

Neutron energy determinations

https://doi.org/10.1016/0375-9474(69)91059-8Get rights and content

Abstract

Neutron energies in the range 3–8 MeV were measured to 0.1 % accuracy. The effects of energy losses in targets and gas cell entrance windows were investigated. Narrow resonances in the interaction of fast neutrons with light nuclei were located with neutrons from the 3 + 1(p, n), 7Li(p, n) and 2H(d, n) reactions.

References (18)

  • F. Manero et al.

    Nucl. Phys.

    (1964)
  • P. Dagley et al.

    Nucl. Phys.

    (1961)
  • R.E. Shamu

    Nucl. Phys.

    (1962)
  • J.C. Davis et al.

    Phys. Lett.

    (1968)
  • D.B. Fossan et al.

    Phys. Rev.

    (1961)
  • D.W. Glasgow et al.

    Bull. Am. Phys. Soc.

    (1963)
  • H.E. Gove

    Phys. Rev. Lett.

    (1958)
  • J.B. Marion

    Rev. Mod. Phys.

    (1966)
  • G. Hardie et al.

    Phys. Rev.

    (1963)
There are more references available in the full text version of this article.

Cited by (16)

  • A routine method for accurate neutron energy measurements in the range 1-20 MeV

    1984, Nuclear Instruments and Methods In Physics Research
View all citing articles on Scopus

Work supported in part by U.S. Atomic Energy Commission.

View full text