NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 11, 2024.

Search: Author = M.P.Unterweger

Found 21 matches.

Back to query form



2016PO08      Phys.Lett. B 761, 281 (2016)

S.Pomme, H.Stroh, J.Paepen, R.Van Ammel, M.Marouli, T.Altzitzoglou, M.Hult, K.Kossert, O.Nahle, H.Schrader, F.Juget, C.Bailat, Y.Nedjadi, F.Bochud, T.Buchillier, C.Michotte, S.Courte, M.W.van Rooy, M.J.van Staden, J.Lubbe, B.R.S.Simpson, A.Fazio, P.De Felice, T.W.Jackson, W.M.Van Wyngaardt, M.I.Reinhard, J.Golya, S.Bourke, T.Roy, R.Galea, J.D.Keightley, K.M.Ferreira, S.M.Collins, A.Ceccatelli, M.Unterweger, R.Fitzgerald, D.E.Bergeron, L.Pibida, L.Verheyen, M.Bruggeman, B.Vodenik, M.Korun, V.Chiste, M.-N.Amiot

Evidence against solar influence on nuclear decay constants

RADIOACTIVITY 209Po, 226Ra, 228Th, 230U, 241Am(α), 3H, 14C, 60Co, 85Kr, 90Sr, 124Sb, 134,137Cs(β-), 54Mn, 55Fe, 57Co, 82,85Sr, 109Cd, 133Ba(EC), 22Na, 65Zn, 207Bi(EC), (β+), 152Eu(β-), (EC), (β+); measured decay products; deduced decay constant vs. solar activity, exponential nature of nuclear decay.

doi: 10.1016/j.physletb.2016.08.038
Citations: PlumX Metrics


2014UN01      Appl.Radiat.Isot. 87, 92 (2014); Erratum Appl.Radiat.Isot. 159, 108976 (2020)

M.P.Unterweger, R.Fitzgerald

Update of NIST half-life results corrected for ionization chamber source-holder instability

RADIOACTIVITY 18F, 22Na, 51Cr, 54Mn, 57,58Co, 62Cu, 65Zn, 67Ga, 85Sr, 88Y, 109Cd, 111In, 113Sn, 123,125I, 127Xe, 139Ce, 153Sm, 169Yb, 181W, 195Au, 201,202Tl, 203Pb, 207Bi(EC), 24Na, 32P, 46Sc, 59Fe, 60Co, 75Se, 85Kr, 99Mo, 99Tc, 103Ru, 110Ag, 125Sb, 131I, 133Xe, 133Ba, 134,137Cs, 140Ba, 140La, 141,144Ce, 152,154,155Eu, 153Gd, 166Ho, 186,188Re, 188W, 192Ir, 198Au, 203Hg, 228Th(β-), 131Xe(IT); analyzed decay products, Eβ, Iβ, Eγ, Iγ; deduced T1/2 updated values, fixed mistake in the propagation of the correction factor, f, and its associated uncertainty. Comparison with the previous measurements at NIST.

doi: 10.1016/j.apradiso.2013.11.017
Citations: PlumX Metrics


2012UN01      Appl.Radiat.Isot. 70, 1892 (2012)

M.P.Unterweger, R.Fitzgerald

Unexpected bias in NIST 4πγ ionization chamber measurements

RADIOACTIVITY 85Kr, 133Xe(β-), 241Am(α), 125I(EC); measured decay products, Eγ, Iγ; deduced corrected values for T1/2 and low-energy γ-rays.

doi: 10.1016/j.apradiso.2012.02.023
Citations: PlumX Metrics


2009PI02      Appl.Radiat.Isot. 67, 636 (2009)

L.Pibida, R.Fitzgerald, M.Unterweger, M.M.Hammond, D.Golas

Measurements of the 82Sr half-life

RADIOACTIVITY 82Sr(EC); measured half-life.

doi: 10.1016/j.apradiso.2008.11.017
Citations: PlumX Metrics

Data from this article have been entered in the XUNDL database. For more information, click here.


2005LI66      J.Radioanal.Nucl.Chem. 263, 311 (2005)

R.M.Lindstrom, M.Blaauw, M.P.Unterweger

QA/QC Procedures, Validation Method, Traceability and Intercomparisons; The half-lives of 24Na, 42K, and 198Au

RADIOACTIVITY 24Na(β-), 42K(β-), 198Au(β-); measured Eγ, Iγ, isotopic T1/2.

doi: 10.1007/s10967-005-0587-y
Citations: PlumX Metrics


2004UN01      Appl.Radiat.Isot. 60, 325 (2004)

M.P.Unterweger, R.M.Lindstrom

Ionization chamber measurements of the half-lives of 24Na, 42K, 76As and 198Au

RADIOACTIVITY 24Na, 42K, 76As, 198Au(β-); measured T1/2. Ionization chamber, comparison with previous results.

doi: 10.1016/j.apradiso.2003.11.035
Citations: PlumX Metrics


2002UN02      Appl.Radiat.Isot. 56, 125 (2002)

M.P.Unterweger

Half-Life Measurements at the National Institute of Standards and Technology

RADIOACTIVITY 22Na, 133Ba, 207Bi(EC); 60Co, 85Kr, 125Sb, 137Cs, 155Eu(β-); 152,154Eu(EC), (β-); measured T1/2. Comparison with previous results.

COMPILATION 3H, 18F, 22,24Na, 32P, 46Sc, 51Cr, 54Mn, 57,58,60Co, 59Fe, 62Cu, 65Zn, 67Ga, 75Se, 85Kr, 85Sr, 88Y, 99Mo, 99mTc, 103Ru, 109Cd, 110mAg, 111In, 113,117mSn, 123,125,131I, 125Sb, 127,131m,133Xe, 133,140Ba, 134,137Cs, 139,141,144Ce, 140La, 152,154,155Eu, 153Gd, 153Sm, 166Ho, 169Yb, 177Lu, 181,188W, 186,188Re, 192Ir, 195,198Au, 201,202Tl, 203Hg, 203Pb, 207Bi, 228Th; compiled T1/2.

doi: 10.1016/S0969-8043(01)00177-4
Citations: PlumX Metrics


2002ZI01      Appl.Radiat.Isot. 56, 315 (2002)

B.E.Zimmerman, J.T.Cessna, M.P.Unterweger

The Standardization of 188W/188Re by 4πβ Liquid Scintillation Spectrometry with the CIEMAT/NIST 3H-Standard Efficiency Tracing Method

RADIOACTIVITY 188W, 188Re(β-); measured Eγ, Iγ, βγ-coin; deduced source standardization. Liquid scintillation counting with efficiency tracing method.

doi: 10.1016/S0969-8043(01)00207-X
Citations: PlumX Metrics


2001ZI01      Appl.Radiat.Isot. 54, 623 (2001)

B.E.Zimmerman, M.P.Unterweger, J.W.Brodack

The Standardization of 177Lu by 4πβ Liquid Scintillation Spectrometry with 3H-Standard Efficiency Tracing

RADIOACTIVITY 177Lu(β-); measured T1/2. Efficiency tracing, standardization.

doi: 10.1016/S0969-8043(00)00316-X
Citations: PlumX Metrics


2000LU17      J.Res.Natl.Inst.Stand.Technol. 105, 541 (2000)

L.L.Lucas, M.P.Unterweger

Comprehensive Review and Critical Evaluation of the Half-Life of Tritium

RADIOACTIVITY 3H(β-); compiled, evaluated T1/2.

doi: 10.6028/jres.105.043
Citations: PlumX Metrics


2000UN02      Appl.Radiat.Isot. 52, 527 (2000)

M.P.Unterweger, L.L.Lucas

Calibration of the National Institute of Standards and Technology tritiated-water standards

RADIOACTIVITY 3H(β-); measured decay products; deduced T1/2. Comparison with the ENSDF data. NBS/NIST tritiated water SRMs.

doi: 10.1016/s0969-8043(99)00205-5
Citations: PlumX Metrics


1997ZI06      J.Phys.(London) G23, 1707 (1997)

B.E.Zimmerman, M.P.Unterweger, J.T.Cessna

The Half-Life of 62Cu

RADIOACTIVITY 62Cu(β+); measured T1/2. 4π liquid scintillator, ionization chamber.

doi: 10.1088/0954-3899/23/11/018
Citations: PlumX Metrics


1996BE48      Nucl.Instrum.Methods Phys.Res. A369, 684 (1996)

M.J.Berger, M.P.Unterweger, J.M.R.Hutchinson

The Influence of Backing and Covering Materials on the 2π-Counting Efficiencies of Beta-Particle Source

RADIOACTIVITY 90Sr(β-); 90Y(β-) [from 90Sr(β--decay)]; 36Cl(β-), (EC), (β+); 204Tl(β-), (EC); 137Cs(β-); 60Co(β-); 99Tc(β-); 147Pm(β-); 14C(β-); 28Al(β-); measured 2π-β counting rates; calculated 2π-β counting rates, Eβ, Iβ(θ). Monte Carlo techniques.

doi: 10.1016/S0168-9002(96)80076-3
Citations: PlumX Metrics


1994CO02      Nucl.Instrum.Methods Phys.Res. A339, 26 (1994)

B.M.Coursey, J.M.Calhoun, J.Cessna, D.B.Golas, F.J.Schima, M.P.Unterweger

Liquid-Scintillation Counting Techniques for the Standardization of Radionuclides used in Therapy

RADIOACTIVITY 109Pd(β-); 114mIn(EC); 123I(EC); 153Gd(EC); 153Sm(β-); 154Eu(EC), (β-); 155Eu(β-); 166Ho(β-); 169Yb(EC); 186Re(EC), (β-); 188Re(β-); measured γ emission rates; deduced deviations from previous data. 32P, 153Sm, 166Ho, 186,188Re(β-) measured T1/2. Liquid scintillation counting, radionuclides standardization for therapy.

doi: 10.1016/0168-9002(94)91773-6
Citations: PlumX Metrics


1994MA51      Nucl.Instrum.Methods Phys.Res. A339, 343 (1994)

J.L.Makepeace, F.E.Clark, J.L.Picolo, N.Coursol, E.Gunther, M.P.Unterweger

Intercomparison of Internal Proportional Gas Counting of 85Kr and 3H

COMPILATION 3H(β-); 85Kr(β-); compiled, reviewed data; deduced internal proportional gas counting international intercomparison.

doi: 10.1016/0168-9002(94)91829-5
Citations: PlumX Metrics


1992UN01      Nucl.Instrum.Methods Phys.Res. A312, 349 (1992)

M.P.Unterweger, D.D.Hoppes, F.J.Schima

New and Revised Half-Life Measurements Results

RADIOACTIVITY 60Co(β-); 137Cs(β-); 85Kr(β-); 22Na(β+), 133Ba(EC); 207Bi(EC), (β+); 125Sb(β-); 152Eu(EC)(β+); 154Eu(EC), (β-), (β-), (β+); 155Eu(β-); measured T1/2; deduced revised T1/2. Comparison with recommended values.

doi: 10.1016/0168-9002(92)90180-C
Citations: PlumX Metrics


1991CO17      Appl.Radiat.Isot. 42, 865 (1991)

B.M.Coursey, J.Cessna, E.Garcia-Torano, D.B.Golas, A.Grau Malonda, D.H.Gray, D.D.Hoppes, J.M.Los Arcos, M.T.Martin-Casallo, F.J.Schima, M.P.Unterweger

The Standardization and Decay Scheme of Rhenium-186

RADIOACTIVITY 186Re(β-), (EC) [from reactor irradiation of 185Re]; measured T1/2, photon emission rates; deduced source standardization. 186Os transition deduced γ-emission probability. Pressurized ionization chamber.

doi: 10.1016/0883-2889(91)90226-Q
Citations: PlumX Metrics


1987CO04      Appl.Radiat.Isot. 38, 31 (1987)

B.M.Coursey, D.D.Hoppes, F.J.Schima, M.P.Unterweger

The Standardization of Samarium-153

RADIOACTIVITY 153Sm(β-); measured T1/2, probability per decay for 103.2 keV γ-ray. 4π β liquid scintillation counter.

doi: 10.1016/0883-2889(87)90232-2
Citations: PlumX Metrics


1983CO20      Int.J.Appl.Radiat.Isotop. 34, 1181 (1983)

B.M.Coursey, D.D.Hoppes, M.P.Unterweger, A.Grau Malonda, R.A.Margolin, R.M.Kessler, R.Manning

Standardization of 18F for Use in Positron-Emission Tomography

RADIOACTIVITY 18F(β+), (EC) [from 20Ne(d, α), E=22 MeV]; measured β+ emission rates. 4π β liquid scintillator, 4π γ ionization chamber, source standardization, 22Na calibration.

doi: 10.1016/0020-708X(83)90186-2
Citations: PlumX Metrics


1980UN01      Appl.Radiat.Isot. 31, 611 (1980)

M.P.Unterweger, B.M.Coursey, F.J.Schima, W.B.Mann

Preparation and Calibration of the 1978 National Bureau of Standards Tritiated-Water Standards

doi: 10.1016/0020-708X(80)90017-4
Citations: PlumX Metrics


1974CA27      Phys.Rev. C10, 2631 (1974)

L.M.Cavallo, F.J.Schima, M.P.Unterweger

Decay of 133Xe-g

RADIOACTIVITY 133gXe; measured T1/2, γ relative intensity. Enriched source, 4πγ pressure chamber, Ge(Li) detector.

doi: 10.1103/PhysRevC.10.2631
Citations: PlumX Metrics


Back to query form


Note: The following list of authors and aliases matches the search parameter M.P.Unterweger: , M.P.UNTERWEGER