NSR Query Results


Output year order : Descending
Format : Normal

NSR database version of April 11, 2024.

Search: Author = C.Mori

Found 28 matches.

Back to query form



2000HA08      Appl.Radiat.Isot. 52, 733 (2000)

N.Hayashi, H.Miyahara, C.Mori, N.Takeuchi, S.Iwamoto, I.Ishikawa

High Accuracy Measurement of the Relative Efficiency Curve and Determination of Gamma-Ray Relative Intensity for 38Cl

RADIOACTIVITY 38Cl(β-) [from 37Cl(n, γ)]; measured Eγ, Iγ; deduced relative γ-ray intensities. High-accuracy efficiency curve.

doi: 10.1016/S0969-8043(99)00237-7
Citations: PlumX Metrics


2000MI03      Appl.Radiat.Isot. 52, 573 (2000)

H.Miyahara, G.Wurdiyanto, H.Nagata, A.Yoshida, K.Yanagida, C.Mori

Precise Measurements of the Gamma-Ray Emission Probabilities of 186Re and 188Re

RADIOACTIVITY 186Re(β-), (EC); 188Re(β-); measured γ-ray emission probabilities.

doi: 10.1016/S0969-8043(99)00212-2
Citations: PlumX Metrics


1999HA16      Nucl.Instrum.Methods Phys.Res. A422, 493 (1999)

N.Hayashi, H.Miyahara, K.Hara, C.Mori, R.F.Fleming, Y.K.Dewaraja, M.A.Ludington

Highly Accurate Determination of γ-Ray Emission Probabilities for 27Mg

RADIOACTIVITY 27Mg(β-); measured Eγ, Iγ; deduced γ-emission probabilities. 27Al deduced branching ratios.

doi: 10.1016/S0168-9002(98)01072-9
Citations: PlumX Metrics


1999MB04      J.Nucl.Sci.Technol.(Tokyo) 36, 1119 (1999)

N.Marnada, H.Nagata, N.Ueda, K.Ikeda, N.Hayashi, C.Mori, H.Miyahara

Precise Measurement of Gamma-Ray Emission Probabilities for 187W by using a Two-Dimensional 4πβ-γ Coincidence System

RADIOACTIVITY 187W(β-) [from 186W(n, γ)]; measured Eγ, Iγ, Eβ, Iβ, γβ-coin; deduced γ-emission probabilities. 187Re deduced levels, ICC.

doi: 10.1080/18811248.1999.9726306
Citations: PlumX Metrics


1999MI01      Nucl.Instrum.Methods Phys.Res. A420, 155 (1999)

H.Miyahara, H.Nagata, T.Furusawa, N.Murakami, C.Mori, N.Takeuchi, T.Genka

Standardisation of 169Yb and Precise Measurement of Gamma-Ray Emission Probabilities

RADIOACTIVITY 169Yb(EC) [from 168Yb(n, γ), E=thermal]; measured Eγ, Iγ, E(ce), I(ce), (ce)γ-coin; deduced γ-ray emission probabilities. 169Tm deduced transitions ICC. Comparison with previous data.

doi: 10.1016/S0168-9002(98)01153-X
Citations: PlumX Metrics


1998MI17      Appl.Radiat.Isot. 49, 1383 (1998)

H.Miyahara, H.Nagata, T.Furusawa, N.Murakami, C.Mori, N.Takeuchi, T.Genka

Gamma-Ray Emission Probabilities of 182Ta

RADIOACTIVITY 182Ta(β-) [from 181Ta(n, γ)]; measured Eγ, Iγ, βγ-coin; deduced γ-emission probabilities.

doi: 10.1016/S0969-8043(97)10079-3
Citations: PlumX Metrics


1997SA65      Nucl.Instrum.Methods Phys.Res. A385, 335 (1997)

H.Sakai, A.Uritani, K.Inoue, Y.Takenaka, C.Mori

New Position Sensing Method for Position-Sensitive Proportional Counter with Neural Network Algorithm

doi: 10.1016/S0168-9002(96)01144-8
Citations: PlumX Metrics


1996MI05      Nucl.Instrum.Methods Phys.Res. A369, 494 (1996)

H.Miyahara, A.Yoshida, G.Wurdiyanto, K.Hara, K.Yanagida, C.Mori

Precise Measurement of the Gamma-Ray Emission Probabilities of 38Cl

RADIOACTIVITY 38Cl(β-) [from thermal neutron irradiation of polyvinylidene chloride film]; measured Eγ, Iγ, γγ-coin. 38Ar levels deduced relative Iγ, β-branching ratio, γ emission probabilities.

doi: 10.1016/S0168-9002(96)80037-4
Citations: PlumX Metrics


1996MI26      Nucl.Instrum.Methods Phys.Res. A374, 193 (1996)

H.Miyahara, K.Usami, C.Mori

Precise Measurement of the Emission Probabilities for the Weak 161 and 223 keV Gamma-Rays of 133Ba

RADIOACTIVITY 133Ba(EC); measured γ spectra. 133Cs levels deduced γ-emission probabilities. 4π β(proportional counter)- hyperpure Ge coincidence system, high precision.

doi: 10.1016/0168-9002(95)01420-9
Citations: PlumX Metrics


1996MO14      Nucl.Instrum.Methods Phys.Res. A369, 544 (1996)

C.Mori, T.Suzuki, S.Koido, A.Uritani, H.Miyahara, K.Yanagida, J.Miyahara, K.Takahashi

Effect of Background Radiation Shielding on Natural Radioactivity Distribution Measurement with Imaging Plate

doi: 10.1016/S0168-9002(96)80047-7
Citations: PlumX Metrics


1996TA13      Nucl.Instrum.Methods Phys.Res. A369, 637 (1996)

Y.Takenaka, A.Uritani, K.Inoue, H.Sakai, K.Kubota, H.Toyokawa, C.Mori

Energy Resolution Enhancement of CdTe Semiconductor Detector Spectra by using a Neural Network Algorithm

RADIOACTIVITY 57Co(EC); measured Eγ, before, after digital sampling, analog shaping methods corrections. Three-layered preceptron neural network, CdTe semi-conductor detector energy resolution studied.

doi: 10.1016/S0168-9002(96)80067-2
Citations: PlumX Metrics


1996TO15      Nucl.Instrum.Methods Phys.Res. A381, 481 (1996)

H.Toyokawa, A.Uritani, C.Mori, M.Yoshizawa, N.Takeda, K.Kudo

Neutron Spectrometer with Position-Sensitive Proportional Counters

RADIOACTIVITY 252Cf(SF); measured fission associated En, In(θ, φ); deduced detector characteristics. Spherical detector.

doi: 10.1016/S0168-9002(96)00755-3
Citations: PlumX Metrics


1995WU09      J.Nucl.Sci.Technol.(Tokyo) 32, 1090 (1995)

G.Wurdiyanto, H.Miyahara, A.Yoshida, K.Yanagida, C.Mori

Precise Measurement of the Gamma-Ray Emission Probabilities for 116mIn with Half-Life of 54.15 min

RADIOACTIVITY 116mIn(β-); measured Eγ, Iγ, βγ-coin. 116Sn levels deduced γ emission probabilities, β-branching ratios, relative Iγ. 4πβ(pc)-γ(hyperpure Ge) counter.

doi: 10.1080/18811248.1995.9731823
Citations: PlumX Metrics


1994GE09      Nucl.Instrum.Methods Phys.Res. A339, 398 (1994)

T.Genka, S.Iwamoto, N.Takeuchi, A.Uritani, C.Mori

Radioactivity Measurements of 192Ir Wire Sources with a Microcalorimeter

RADIOACTIVITY 192Ir(EC), (β-); measured activity. Wire sources, microcalorimeter.

doi: 10.1016/0168-9002(94)91839-2
Citations: PlumX Metrics


1994MI04      Appl.Radiat.Isot. 45, 219 (1994)

H.Miyahara, H.Matumoto, C.Mori

Precise Measurement of the Gamma-Ray Emission Probability for 175Yb

RADIOACTIVITY 175Yb(β-); measured βγ-coin, Eγ, Iγ. 175Lu levels deduced γ-emission probabilities. 4π β(pressurized proportional counter)-γ(hyperpure Ge detector) coincidence apparatus.

doi: 10.1016/0969-8043(94)90014-0
Citations: PlumX Metrics


1994MI22      Nucl.Instrum.Methods Phys.Res. A339, 203 (1994)

H.Miyahara, H.Matumoto, C.Mori, N.Takeuchi, T.Genka

Determination of Gamma-Ray Emission Probabilities for 75Se, 166mHo and 192Ir by a Self-Consistent Method

RADIOACTIVITY 75Se(EC); 166mHo(β-); 75As, 166Er, 192Pt levels deduced emission probabilities.

doi: 10.1016/0168-9002(94)91805-8
Citations: PlumX Metrics


1994MI35      Nucl.Instrum.Methods Phys.Res. A353, 229 (1994)

H.Miyahara, H.Matumoto, G.Wurdiyanto, K.Yanagida, Y.Takenaka, A.Yoshida, C.Mori

Gamma-Ray Emission Probability Measurement by a Two-Dimensional 4πβ-γ Coincidence System

RADIOACTIVITY 128I(β-), (β+), (EC); measured βγ-coin. 128Xe levels deduced γ emission probabilities. 128Te levels deduced ce-emission probabilities. 4π β proportional counter operated with CF4 gas, hyperpure Ge detector coincidence system, two-dimension data acquisition.

doi: 10.1016/0168-9002(94)91644-6
Citations: PlumX Metrics


1994UR02      Nucl.Instrum.Methods Phys.Res. A339, 377 (1994)

A.Uritani, T.Genka, C.Mori, D.F.G.Reher

Analytical Calculations on Radioactivity Measurements of 192Ir Metallic Sources with a Calibrated Ionization Chamber

RADIOACTIVITY 192Ir(EC), (β-); calculated photon self-attenuation influence on calibrated ionization chamber current; deduced correction factor to get true activity. Metallic wire, aqueous standard sources.

doi: 10.1016/0168-9002(94)91834-1
Citations: PlumX Metrics


1993MI13      Nucl.Instrum.Methods Phys.Res. A324, 219 (1993)

H.Miyahara, K.Hara, C.Mori, Y.Kasugai, K.Kawade

Precise Measurement of γ-Ray Emission Probabilities for 66Cu

RADIOACTIVITY 66Cu(β-) [from 65Cu(n, γ), E=thermal]; measured Eγ, Iγ, βγ-coin. 66Zn levels deduced γ-emission probabilities.

doi: 10.1016/0168-9002(93)90979-R
Citations: PlumX Metrics


1993MI31      Nucl.Instrum.Methods Phys.Res. A336, 385 (1993)

H.Miyahara, H.Matumoto, K.Yanagida, Y.Takenaka, C.Mori

Emission Probability for the 443 keV γ-Rays of 128I

RADIOACTIVITY 128I(EC), (β+), (β-); measured βγ-coin. 128Xe level deduced γ-emission probability.

doi: 10.1016/0168-9002(93)91126-8
Citations: PlumX Metrics


1993YO08      Nucl.Instrum.Methods Phys.Res. A330, 158 (1993)

M.Yoshida, T.Yamamoto, Y.Wu, T.Aratani, A.Uritani, C.Mori

Direct Measurement of Gaseous Activities by Diffusion-In Long Proportional Counter Method

RADIOACTIVITY 37Ar(EC) [from 36Ar(n, γ), E reactor]; measured K-, L-Auger electron spectra. Gaseous activities direct measurement, diffusion in long proportional counter method.

doi: 10.1016/0168-9002(93)91318-H
Citations: PlumX Metrics


1992MI02      Appl.Radiat.Isot. 43, 377 (1992)

H.Miyahara, C.Mori

Standardization of 133Ba by Two-Dimensional Extrapolation

RADIOACTIVITY 133Ba(EC); measured βγ-coin; deduced efficiency function. 4πβ(proportional counter)-γ(hyperpure Ge) coincidence technique.

doi: 10.1016/0883-2889(92)90109-R
Citations: PlumX Metrics


1992MI04      Nucl.Instrum.Methods Phys.Res. A312, 71 (1992)

H.Miyahara, K.Hara, C.Mori

Application of CF4 Gas to 4πβ-γ Coincidence Counting

RADIOACTIVITY 60Co(β-); 134Cs(EC), (β-); 152Eu(β-)(β+), (EC); 133Ba(EC); 27Mg(β-); measured γγ-coin efficiency function. 4π βγ-counting, proportional counter, CF gas at atmospheric pressure.

doi: 10.1016/0168-9002(92)90130-V
Citations: PlumX Metrics


1992MI05      Nucl.Instrum.Methods Phys.Res. A312, 359 (1992)

H.Miyahara, Y.Nozue, C.Mori

Standardisation of 103Ru and Measurement of the Emission Probabilities for the Principal γ-Rays

RADIOACTIVITY 103Ru(β-); measured βγ-coincidence efficiency, I(ce); deduced source standardization. 103Rh transitions deduced γ-emission probabilities.

doi: 10.1016/0168-9002(92)90182-4
Citations: PlumX Metrics


1992MO10      Nucl.Instrum.Methods Phys.Res. A312, 189 (1992)

C.Mori, T.Yamamoto, T.Suzuki, A.Uritani, K.Yanagida, Y.Wu, T.Watanabe, M.Yoshida

Radioactivity Measurement of 85Kr with Position-Sensitive Proportional Counter

RADIOACTIVITY 85Kr(β-); measured β-spectra; deduced activity. Direct measurement technique, position-sensitive proportional counter.

doi: 10.1016/0168-9002(92)90151-S
Citations: PlumX Metrics


1991MI04      Appl.Radiat.Isot. 42, 485 (1991)

H.Miyahara, Y.Nozue, C.Mori

Measurement of the Emission Probability for the 1077 keV γ-Ray of 86Rb

RADIOACTIVITY 86Rb; measured Iγ, disintegration rate following β-decay. 86Sr level deduced γ-emission probability.

doi: 10.1016/0883-2889(91)90110-M
Citations: PlumX Metrics


1990MO39      Nucl.Instrum.Methods Phys.Res. A299, 128 (1990)

C.Mori, T.Suzuki, A.Uritani, T.Yamamoto, K.Yanagida, T.Watanabe, M.Yoshida

Application of a Logarithmic Amplifier to a Charge-Division-Type Position-Sensitive Proportional Counter

RADIOACTIVITY 14C; measured Eβ, Iβ. Logarithmic amplifier, charge-division-type position sensitive proportional counter.

doi: 10.1016/0168-9002(90)90762-U
Citations: PlumX Metrics


1987MO19      Appl.Radiat.Isot. 38, 851 (1987)

C.Mori, T.Aratani, T.Watanabe, M.Yoshida

Direct Measurement of Radioactivity of 14C Gaseous Samples with Position - Sensitive Proportional Counter

RADIOACTIVITY 14C(β-); measured β-spectra. Position sensitive proportional counter.

doi: 10.1016/0883-2889(87)90183-3
Citations: PlumX Metrics


Back to query form