NSR Query Results
Output year order : Descending NSR database version of April 11, 2024. Search: Author = A.Uritani Found 11 matches. 2005SH37 Phys.Rev. C 72, 025808 (2005) T.Shizuma, H.Utsunomiya, P.Mohr, T.Hayakawa, S.Goko, A.Makinaga, H.Akimune, T.Yamagata, M.Ohta, H.Ohgaki, Y.-W.Lui, H.Toyokawa, A.Uritani, S.Goriely Photodisintegration cross section measurements on 186W, 187Re, and 188Os: Implications for the Re-Os cosmochronology NUCLEAR REACTIONS 186W, 187Re, 188Os(γ, n), E=7.3-10.9 MeV; measured σ. 185W, 186Re, 187Os(n, γ), E < 100 keV; calculated capture σ. Astrophysical implications discussed.
doi: 10.1103/PhysRevC.72.025808
2003HA55 Phys.Rev. D 68, 072001 (2003) K.Y.Hara, H.Utsunomiya, S.Goko, H.Akimune, T.Yamagata, M.Ohta, H.Toyokawa, K.Kudo, A.Uritani, Y.Shibata, Y.-W.Lui, H.Ohgaki Photodisintegration of deuterium and Big Bang nucleosynthesis NUCLEAR REACTIONS 2H(γ, n), E=2.3-4.5 MeV; measured products, En, In; deduced σ, σ(E). Data were imported from EXFOR entry M0668.
doi: 10.1103/PhysRevD.68.072001
1997SA65 Nucl.Instrum.Methods Phys.Res. A385, 335 (1997) H.Sakai, A.Uritani, K.Inoue, Y.Takenaka, C.Mori New Position Sensing Method for Position-Sensitive Proportional Counter with Neural Network Algorithm
doi: 10.1016/S0168-9002(96)01144-8
1996MO14 Nucl.Instrum.Methods Phys.Res. A369, 544 (1996) C.Mori, T.Suzuki, S.Koido, A.Uritani, H.Miyahara, K.Yanagida, J.Miyahara, K.Takahashi Effect of Background Radiation Shielding on Natural Radioactivity Distribution Measurement with Imaging Plate
doi: 10.1016/S0168-9002(96)80047-7
1996TA13 Nucl.Instrum.Methods Phys.Res. A369, 637 (1996) Y.Takenaka, A.Uritani, K.Inoue, H.Sakai, K.Kubota, H.Toyokawa, C.Mori Energy Resolution Enhancement of CdTe Semiconductor Detector Spectra by using a Neural Network Algorithm RADIOACTIVITY 57Co(EC); measured Eγ, before, after digital sampling, analog shaping methods corrections. Three-layered preceptron neural network, CdTe semi-conductor detector energy resolution studied.
doi: 10.1016/S0168-9002(96)80067-2
1996TO15 Nucl.Instrum.Methods Phys.Res. A381, 481 (1996) H.Toyokawa, A.Uritani, C.Mori, M.Yoshizawa, N.Takeda, K.Kudo Neutron Spectrometer with Position-Sensitive Proportional Counters RADIOACTIVITY 252Cf(SF); measured fission associated En, In(θ, φ); deduced detector characteristics. Spherical detector.
doi: 10.1016/S0168-9002(96)00755-3
1994GE09 Nucl.Instrum.Methods Phys.Res. A339, 398 (1994) T.Genka, S.Iwamoto, N.Takeuchi, A.Uritani, C.Mori Radioactivity Measurements of 192Ir Wire Sources with a Microcalorimeter RADIOACTIVITY 192Ir(EC), (β-); measured activity. Wire sources, microcalorimeter.
doi: 10.1016/0168-9002(94)91839-2
1994UR02 Nucl.Instrum.Methods Phys.Res. A339, 377 (1994) A.Uritani, T.Genka, C.Mori, D.F.G.Reher Analytical Calculations on Radioactivity Measurements of 192Ir Metallic Sources with a Calibrated Ionization Chamber RADIOACTIVITY 192Ir(EC), (β-); calculated photon self-attenuation influence on calibrated ionization chamber current; deduced correction factor to get true activity. Metallic wire, aqueous standard sources.
doi: 10.1016/0168-9002(94)91834-1
1993YO08 Nucl.Instrum.Methods Phys.Res. A330, 158 (1993) M.Yoshida, T.Yamamoto, Y.Wu, T.Aratani, A.Uritani, C.Mori Direct Measurement of Gaseous Activities by Diffusion-In Long Proportional Counter Method RADIOACTIVITY 37Ar(EC) [from 36Ar(n, γ), E reactor]; measured K-, L-Auger electron spectra. Gaseous activities direct measurement, diffusion in long proportional counter method.
doi: 10.1016/0168-9002(93)91318-H
1992MO10 Nucl.Instrum.Methods Phys.Res. A312, 189 (1992) C.Mori, T.Yamamoto, T.Suzuki, A.Uritani, K.Yanagida, Y.Wu, T.Watanabe, M.Yoshida Radioactivity Measurement of 85Kr with Position-Sensitive Proportional Counter RADIOACTIVITY 85Kr(β-); measured β-spectra; deduced activity. Direct measurement technique, position-sensitive proportional counter.
doi: 10.1016/0168-9002(92)90151-S
1990MO39 Nucl.Instrum.Methods Phys.Res. A299, 128 (1990) C.Mori, T.Suzuki, A.Uritani, T.Yamamoto, K.Yanagida, T.Watanabe, M.Yoshida Application of a Logarithmic Amplifier to a Charge-Division-Type Position-Sensitive Proportional Counter RADIOACTIVITY 14C; measured Eβ, Iβ. Logarithmic amplifier, charge-division-type position sensitive proportional counter.
doi: 10.1016/0168-9002(90)90762-U
Back to query form |