Dataset referencing 2011SO11
Eur.Phys.J. A 47, 40 (2011)
J.Souin, T.Eronen, P.Ascher, L.Audirac, J.Aysto, B.Blank, V.-V.Elomaa, J.Giovinazzo, J.Hakala, A.Jokinen, V.S.Kolhinen, P.Karvonen, I.D.Moore, S.Rahaman, J.Rissanen, A.Saastamoinen, J.C.Thomas
Precision half-life and Q -value measurement of the super-allowed β emitter 30S
RADIOACTIVITY 30S(EC) [from Ni2P(p, X), E=35 MeV]; measured cyclotron frequency ratio, Eβ, Iβ, Eγ, Iγ; deduced Q-value, T1/2 and uncertainties. JYFLTRAP Penning trap setup.
doi: 10.1140/epja/i2011-11040-5